Department of Surgery, Scott & White Memorial Hospital, Temple, Texas 76503, USA.
J Surg Res. 2013 Sep;184(1):157-63. doi: 10.1016/j.jss.2013.06.036. Epub 2013 Jul 11.
Surgical safety programs have been shown to reduce patient harm; however, there is variable compliance. The purpose of this study is to determine if innovative technology such as Quick Response (QR) codes can facilitate surgical safety initiatives.
We prospectively evaluated the use of QR codes during the surgical time-out for 40 operations. Feasibility and accuracy were assessed. Perceptions of the current time-out process and the QR code application were evaluated through surveys using a 5-point Likert scale and binomial yes or no questions.
At baseline (n = 53), survey results from the surgical team agreed or strongly agreed that the current time-out process was efficient (64%), easy to use (77%), and provided clear information (89%). However, 65% of surgeons felt that process improvements were needed. Thirty-seven of 40 (92.5%) QR codes scanned successfully, of which 100% were accurate. Three scan failures resulted from excessive curvature or wrinkling of the QR code label on the body. Follow-up survey results (n = 33) showed that the surgical team agreed or strongly agreed that the QR program was clearer (70%), easier to use (57%), and more accurate (84%). Seventy-four percent preferred the QR system to the current time-out process.
QR codes accurately transmit patient information during the time-out procedure and are preferred to the current process by surgical team members. The novel application of this technology may improve compliance, accuracy, and outcomes.
外科安全计划已被证明可减少患者伤害;然而,其合规性存在差异。本研究的目的是确定创新技术(如快速响应 QR 码)是否可以促进外科安全计划。
我们前瞻性地评估了在 40 例手术的手术暂停期间使用 QR 码的情况。评估了可行性和准确性。通过使用 5 分李克特量表和二进制是或否问题的问卷调查,评估了当前暂停流程和 QR 码应用的看法。
在基线时(n = 53),外科团队的调查结果表明,当前的暂停流程效率高(64%)、易于使用(77%)并提供了清晰的信息(89%)。然而,65%的外科医生认为需要改进流程。40 个 QR 码中有 37 个(92.5%)成功扫描,其中 100%是准确的。有 3 次扫描失败是由于 QR 码标签在身体上的过度弯曲或起皱造成的。后续调查结果(n = 33)显示,外科团队认为 QR 程序更清晰(70%)、更易于使用(57%)且更准确(84%)。74%的人更喜欢 QR 系统而不是当前的暂停流程。
QR 码在暂停程序中准确传输患者信息,并且外科团队成员更喜欢这种新技术。这种技术的新颖应用可能会提高合规性、准确性和结果。