Suppr超能文献

五步母子技术:使用4F小儿导管进行5F桡动脉途径复杂病变冠状动脉介入治疗

The 4-in-5 mother-child technique: 5 Fr transradial coronary intervention for complex lesions using a 4 Fr child catheter.

作者信息

Tobita Kazuki, Takeshita Satoshi, Saito Shigeru

机构信息

Department of Cardiology and Catheterization Laboratory, Shonan Kamakura General Hospital, Kamakura, Japan.

出版信息

J Invasive Cardiol. 2013 Aug;25(8):406-8.

Abstract

Small 5 Fr guiding catheters are now used in percutaneous coronary intervention (PCI). However, when treating severely calcified and/or tortuous complex coronary lesions, the back-up support of a 5 Fr guiding catheter is often insufficient. We previously developed a 4 Fr child catheter (Kiwami ST-01; Terumo Corporation) and proposed a 4 Fr double-coaxial technique ("mother-child" configuration) to facilitate stent implantation in treating complex coronary lesions. In this manuscript, we report 2 cases of 5 Fr transradial coronary intervention in which stent delivery failed with conventional techniques. In these 2 cases, our 4 Fr double-coaxial technique was employed, and stents were successfully delivered to the target lesions. To the best of our knowledge, this is the first report demonstrating the potential of the 4-in-5 technique during 5 Fr PCI.

摘要

小型5F引导导管目前用于经皮冠状动脉介入治疗(PCI)。然而,在治疗严重钙化和/或迂曲的复杂冠状动脉病变时,5F引导导管的支撑往往不足。我们之前研发了一种4F子导管(Kiwami ST-01;泰尔茂株式会社),并提出了一种4F双同轴技术(“母子”配置),以促进在治疗复杂冠状动脉病变时植入支架。在本手稿中,我们报告了2例5F经桡动脉冠状动脉介入治疗病例,其中传统技术未能成功输送支架。在这2例病例中,我们采用了4F双同轴技术,支架成功输送至目标病变。据我们所知,这是第一份证明5F PCI期间5合4技术潜力的报告。