Suppr超能文献

4.7 T下离体灌注大鼠心脏的回波平面成像:Langendorff法与工作心脏制备方法的比较

Echo planar imaging of isolated perfused rat hearts at 4.7 T: a comparison of Langendorff and working heart preparations.

作者信息

Blackband S J, Chatham J C, O'Dell W, Day S

机构信息

Department of Radiology, Johns Hopkins School of Medicine, Baltimore, Maryland 21205.

出版信息

Magn Reson Med. 1990 Aug;15(2):240-5. doi: 10.1002/mrm.1910150207.

Abstract

The implementation of echo planar imaging at 4.7 T is demonstrated using a homebuilt gradient and radiofrequency assembly. The application of such a technique to the study of the isolated perfused rat heart is demonstrated. Langendorff and working heart perfusion preparations are compared and changes in the left ventricular volume shown are to be much larger in the working heart preparation. Such a methodology is expected to provide a useful model for the study of cardiac function and dynamics in the normal and diseased states under controlled perfusion conditions.

摘要

使用自制的梯度和射频组件展示了在4.7 T下进行回波平面成像的过程。展示了这种技术在离体灌注大鼠心脏研究中的应用。比较了Langendorff灌注和工作心脏灌注制备方法,结果表明工作心脏制备中左心室体积的变化要大得多。预计这种方法将为在可控灌注条件下研究正常和患病状态下的心脏功能和动力学提供一个有用的模型。