Department of Medicine, Fletcher Allen Health Care, University of Vermont, 111 Colchester Avenue, Burlington, VT, 05401, USA,
J Nucl Cardiol. 2013 Dec;20(6):1069-75. doi: 10.1007/s12350-013-9768-1. Epub 2013 Aug 17.
Stress only SPECT myocardial perfusion imaging (MPI) is a validated strategy to streamline cardiac diagnostic imaging. The potential use of Rb82 PET stress only MPI has not been investigated.
Stress images from 200 Rb82 PET-MPI were reviewed by two blinded readers and categorized as not requiring additional rest images (normal) or requiring additional images (abnormal or equivocal). No additional images were deemed necessary for 95 (48%) and 99 (50%) by the two blinded readers. The stress only interpretation was compared to the previous read of the complete rest-stress study. The rate of detecting a normal result with stress only reading was 76%-79% with a negative predictive value of 94%-95%. Clinical predictors of a normal stress only PET-MPI included lower age, the absence of CAD, and female gender, but not body mass index. Blinded reads of 50 additional consecutive PET-MPI from patients with selected clinical predictors (age <65 years, no known CAD) were then performed. Of these, 40 (80%) were normal by previous rest-stress reading, and 34 (68%) were categorized as not requiring additional images after stress only reading. PET stress only imaging would have resulted in a mean reduction of radiation exposure of 2.4 mSv per study according to a published radiation estimate.
Stress only Rb82 PET-MPI is a feasible strategy to reduce resource utilization and radiation exposure associated with MPI. This strategy would be most applicable to patients with a lower pretest likelihood.
仅应激 SPECT 心肌灌注成像(MPI)是一种经过验证的策略,可以简化心脏诊断成像。尚未研究 Rb82 PET 仅应激 MPI 的潜在用途。
由两名盲法读者对 200 例 Rb82 PET-MPI 的应激图像进行了回顾,并将其分类为不需要额外静息图像(正常)或需要额外图像(异常或不确定)。两名盲法读者均认为不需要额外的 95 例(48%)和 99 例(50%)图像。仅应激解读与之前完整静息-应激研究的解读进行了比较。仅应激阅读检测正常结果的率为 76%-79%,阴性预测值为 94%-95%。仅应激 PET-MPI 正常的临床预测因素包括年龄较低、无 CAD 和女性,但体重指数除外。然后对 50 例具有选定临床预测因素(年龄<65 岁,无已知 CAD)的患者的连续 PET-MPI 进行了盲法阅读。其中,40 例(80%)根据之前的静息-应激阅读结果正常,34 例(68%)在仅应激阅读后被归类为不需要额外图像。根据发表的辐射估计,PET 仅应激成像将使每个研究的平均辐射暴露减少 2.4 mSv。
Rb82 PET 仅应激 MPI 是一种可行的策略,可以减少与 MPI 相关的资源利用和辐射暴露。该策略最适用于具有较低的术前可能性的患者。