Highly cross-linked polyethylene (HXPE) in total hip arthroplasty (THA) has been shown to significantly decrease wear rates compared with conventional polyethylene (CPE). However, crosslinking, thermal treatment and oxidation can decrease the mechanical properties of PE, and several cases of fracture of remelted HXPE liners were reported. We present, for the first time, unexpected failures of THA with the use of annealed HXPE liners in two patients occurring at 7 and 8 years after operation. Operative findings revealed dislocated liners from the metal shell and a fracture of the superior rim at the rim-dome junction in both liners. Scanning electron microscopy showed that the cracks initiated at the rim and propagated toward the articular surface. Both liners showed generally a low amount of oxidation (less than 1.00) at the articular surface and low wear rates; however, oxidation at the rim was relatively higher (mean 1.55). These findings suggested that decreased mechanical properties at the rim-dome junction due to cross-linking, annealing and oxidation might have been caused breakage of the HXPE liners after a long implantation time, although the annealed HXPE achieved low degree of wear.
在全髋关节置换术中,与传统聚乙烯(CPE)相比,高度交联聚乙烯(HXPE)已被证明可显著降低磨损率。然而,交联、热处理和氧化会降低 PE 的机械性能,并且已经报道了几例再熔化的 HXPE 衬垫断裂的情况。我们首次报告了在两名患者中使用退火 HXPE 衬垫的全髋关节置换术出现的意外失败,这两名患者分别在手术后 7 年和 8 年出现了这种情况。手术发现发现衬垫从金属外壳中脱位,并且在两个衬垫的边缘-穹顶连接处发生了上边缘的断裂。扫描电子显微镜显示,裂纹从边缘开始,并向关节表面扩展。两个衬垫的关节表面氧化程度均较低(小于 1.00),磨损率也较低;然而,边缘的氧化程度相对较高(平均 1.55)。这些发现表明,交联、退火和氧化导致边缘-穹顶连接处的机械性能下降,可能导致 HXPE 衬垫在长时间植入后发生断裂,尽管退火的 HXPE 实现了较低的磨损程度。