托盘间隙对缩合型硅橡胶、加成型硅橡胶和聚醚印模材料精度影响的评估:一项体外研究。

Evaluation of effect of tray space on the accuracy of condensation silicone, addition silicone and polyether impression materials: an in vitro study.

作者信息

Kumar Varun, Aeran Himanshu

机构信息

Department of Prosthodontics & Dental Material Sciences, Kalka Dental College, Delhi-Haridwar-Partapur By Pass Road, Meerut, Uttar Pradesh India.

出版信息

J Indian Prosthodont Soc. 2012 Sep;12(3):154-60. doi: 10.1007/s13191-012-0124-y. Epub 2012 Jun 4.

Abstract

Optimal thickness of impression materials in the custom tray in order to get the most accurate impression. To investigate the effect of different tray spacer thickness on the accuracy and the dimensional stability of impressions made from monophasic condensation silicone, addition silicone and polyether impression materials. Three different types of elastomeric monophasic impression materials were used for making the impression of a master die with tray having tray spacer thickness of 2, 4 and 6 mm. Each type of impression was poured in die stone after 1 h. Each cast was analyzed by a travelling microscope and compared with the master die. The data was tabulated and subjected to statistical evaluation. The results of the study indicated that the impressions made from 2 to 4 mm spaced trays produced more accurate stone casts when compared to 6 mm spaced tray. No statistical significant differences were observed between the accuracy and dimensional stability of the three materials tested. Minimum changes were observed when the cast was poured after 1 h and the tray space was 2 mm for all the materials tested. It is therefore advisable not to exceed tray space of 2 mm.

摘要

为获得最准确的印模,需确定定制托盘中印模材料的最佳厚度。研究不同托盘间隔厚度对单相缩合硅橡胶、加成型硅橡胶和聚醚印模材料所制印模的准确性和尺寸稳定性的影响。使用三种不同类型的弹性单相印模材料,通过托盘间隔厚度为2、4和6毫米的托盘对母模进行印模制取。每种印模在1小时后灌注石膏模型。使用移动显微镜对每个模型进行分析,并与母模进行比较。将数据制成表格并进行统计评估。研究结果表明,与间隔6毫米的托盘相比,间隔2至4毫米的托盘所制印模产生的石膏模型更准确。在所测试的三种材料的准确性和尺寸稳定性之间未观察到统计学上的显著差异。对于所有测试材料,当在1小时后灌注模型且托盘间隔为2毫米时,观察到的变化最小。因此,建议托盘间隔不要超过2毫米。

相似文献

8
Comparison of dimensional accuracy of elastomeric impression materials using 3D laser scanner.使用三维激光扫描仪比较弹性印模材料的尺寸精度
Med J Armed Forces India. 2022 Sep;78(Suppl 1):S55-S60. doi: 10.1016/j.mjafi.2021.05.019. Epub 2021 Jul 30.

本文引用的文献

1
A comparison of elastic impression materials.弹性印模材料的比较
J Prosthet Dent. 1975 Sep;34(3):305-13. doi: 10.1016/0022-3913(75)90108-0.
3
Linear dimensional changes in addition curing silicone impression materials.
J Prosthet Dent. 1982 Apr;47(4):411-3. doi: 10.1016/s0022-3913(82)80092-9.
5
Dimensional stability of elastomeric impression materials in custom-made and stock trays.
J Prosthet Dent. 1984 Oct;52(4):514-7. doi: 10.1016/0022-3913(84)90336-6.
6
Clinically oriented evaluation of the accuracy of commonly used impression materials.
J Prosthet Dent. 1986 Jul;56(1):4-8. doi: 10.1016/0022-3913(86)90272-6.
7
Accuracy of addition silicones as a function of technique.加成型硅橡胶的准确性与技术的关系。
J Prosthet Dent. 1986 Feb;55(2):197-203. doi: 10.1016/0022-3913(86)90342-2.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验