Abstract

OBJECTIVE

To establish an experimental model for lower pole nephrectomy using 3-dimensional endocasts of human kidneys.

METHODS

We studied 38 adult kidneys. The ureters, veins, and arteries were dissected and injected with yellow, blue, and red polyester resin, respectively. While the resins were still in a gel state, we performed lower pole guillotine sections at various distances from the hilar zone. The sample was divided into 4 groups: A, At hilar zone (11 kidneys); B, 0.5 cm from the hilar zone (12 kidneys); C, 1.0 cm from the hilar zone (8 kidneys); and D, 1.5 cm from the hilar zone (7 kidneys).

RESULTS A

At hilar zone-arteries: in 4 cases (36.36%), the lower segmental artery (LSA) was injured; veins: in 5 cases (45.45%), the lower venous trunk was injured (LVT). B: 0.5 cm from the hilar zone-arteries: the LSA was injured in 1 case (8.3%); veins: in 4 cases (33.3%), a lesion occurred to the LVT. C: 1.0 cm from the hilar zone-arteries: there were no lesions to LSA, but the infundibular arteries were damaged in all cases; veins: the interlobular veins were damaged in 3 of 11 cases (27.27%). D: 1.5 from the hilar zone-arteries: we observed lesions to the infundibular arteries in all cases; veins: arcuate veins were damaged in 4 of 7 cases (57.14%).

CONCLUSION

Lower pole nephrectomies performed at less than 1.0 cm from the hilar zone presented a significantly high incidence of injuries to large arteries and veins.

摘要

目的

建立一种使用人类肾脏 3 维内铸型的下极肾切除术实验模型。

方法

我们研究了 38 个成人肾脏。输尿管、静脉和动脉分别用黄色、蓝色和红色聚酯树脂解剖和注射。当树脂仍处于凝胶状态时,我们在下极区域进行了不同距离的断头切除。样本分为 4 组:A 组,在肾门区域(11 个肾脏);B 组,距离肾门 0.5cm(12 个肾脏);C 组,距离肾门 1.0cm(8 个肾脏);D 组,距离肾门 1.5cm(7 个肾脏)。

结果

A 组,在肾门区域-动脉:4 例(36.36%)下节段动脉(LSA)受损;静脉:5 例(45.45%)下静脉干受损(LVT)。B 组,距离肾门 0.5cm-动脉:1 例(8.3%)LSA 受损;静脉:4 例(33.3%)LVT 出现病变。C 组,距离肾门 1.0cm-动脉:LSA 无病变,但所有情况下漏斗动脉受损;静脉:11 例中有 3 例(27.27%)间叶静脉受损。D 组,距离肾门 1.5cm-动脉:所有情况下均观察到漏斗动脉病变;静脉:7 例中有 4 例(57.14%)弓形静脉受损。

结论

距离肾门小于 1.0cm 进行下极肾切除术时,大血管和静脉损伤的发生率明显较高。

相似文献

1
Experimental model of lower pole nephrectomy using human 3-dimensional endocasts: analysis of vascular injuries.
Urology. 2013 Nov;82(5):1049-53. doi: 10.1016/j.urology.2013.07.026. Epub 2013 Aug 31.
2
Experimental model of upper-pole nephrectomy using human tridimensional endocasts: analysis of vascular injuries.
J Endourol. 2011 Jan;25(1):113-8. doi: 10.1089/end.2010.0214. Epub 2010 Oct 23.
3
Cranial pole nephrectomy in the pig model: anatomic analysis of arterial injuries in tridimensional endocasts.
J Endourol. 2012 Jun;26(6):716-21. doi: 10.1089/end.2011.0489. Epub 2012 Feb 21.
9
The dilemma of the crossing vessel at the ureteropelvic junction: precise anatomic study.
J Endourol. 1996 Oct;10(5):411-5. doi: 10.1089/end.1996.10.411.
10
[Segmental polar nephrectomy].
Zhonghua Wai Ke Za Zhi. 1990 Feb;28(2):105-7, 127.

引用本文的文献

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验