Fielden Samuel W, Mugler John P, Hagspiel Klaus D, Norton Patrick T, Kramer Christopher M, Meyer Craig H
Department of Biomedical Engineering, University of Virginia, Charlottesville, Virginia, USA.
J Magn Reson Imaging. 2014 Jun;39(6):1468-76. doi: 10.1002/jmri.24325. Epub 2013 Sep 4.
To develop and assess a three-dimensional refocused turbo spin-echo (rTSE) sequence for generating peripheral angiograms. This sequence combines the rapid T2 -weighting of TSE and the better flow performance of the fully-refocused gradients of balanced steady state free precession (bSSFP), along with bSSFP-style phase alternation of refocusing radiofrequency (RF) pulses.
The signal behavior generated by such a sequence was explored through Bloch equation simulations. The rTSE and TSE sequences were both used to generate peripheral angiograms in nine normal volunteers. The signal to noise ratio, contrast resolution, and vessel sharpness of the resulting images were used as bases for comparison. Additionally, the rTSE sequence was applied in four patients with peripheral artery disease to preliminarily assess its efficacy in a clinical setting through quality scoring by two experienced radiologists.
The rTSE's RF phase alternation approach out-performs a simple balanced-gradient CPMG (Carr-Purcell-Meiboom-Gill) -style TSE sequence in the presence of B0 and B1 inhomogeneities. In volunteers, the rTSE sequence yielded better arterial-venous contrast (0.378 ± 0.145 versus 0.155 ± 0.202; P < 0.01) and increased vessel sharpness (0.340 ± 0.034 versus 0.263 ± 0.034; P < 0.005) over TSE images. Stenoses visible in conventional angiographic images in patients were successfully imaged with the rTSE sequence; however, image quality scores in patients were lower than in volunteers (1.2 ± 0.38 versus 3.0 ± 1.0; P < 0.05).
The rTSE sequence generates nonsubtractive, flow-independent, peripheral MR angiograms with better arterial-venous contrast and vessel sharpness in normal volunteers than a conventional TSE sequence.
开发并评估一种用于生成外周血管造影的三维重聚焦涡轮自旋回波(rTSE)序列。该序列结合了TSE快速的T2加权、平衡稳态自由进动(bSSFP)完全重聚焦梯度更好的血流表现,以及重聚焦射频(RF)脉冲的bSSFP式相位交替。
通过布洛赫方程模拟探索了该序列产生的信号行为。rTSE和TSE序列均用于对9名正常志愿者进行外周血管造影。所得图像的信噪比、对比分辨率和血管清晰度用作比较依据。此外,rTSE序列应用于4例外周动脉疾病患者,由两名经验丰富的放射科医生通过质量评分初步评估其在临床环境中的疗效。
在存在B0和B1不均匀性的情况下,rTSE的RF相位交替方法优于简单的平衡梯度CPMG(Carr-Purcell-Meiboom-Gill)式TSE序列。在志愿者中,与TSE图像相比,rTSE序列产生了更好的动静脉对比度(0.378±0.145对0.155±0.202;P<0.0l)并提高了血管清晰度(0.340±0.034对0.263±0.034;P<0.005)。患者常规血管造影图像中可见的狭窄用rTSE序列成功成像;然而,患者的图像质量评分低于志愿者(1.2±0.38对3.0±1.0;P<0.05)。
与传统TSE序列相比,rTSE序列在正常志愿者中可生成非减影、血流无关的外周磁共振血管造影,具有更好的动静脉对比度和血管清晰度。