Mixing implants with differing metallic compositions has been avoided for fear of galvanic corrosion and subsequent failure of the implants and of bone healing. The purpose of this study was to evaluate upper-extremity fractures treated with open reduction and internal fixation with metallic implants that differed in metallic composition placed on the same bone. The authors studied the effects of using both stainless steel and titanium implants on fracture healing, implant failure, and other complications associated with this method of fixation. Their hypothesis was that combining these metals on the same bone would not cause clinically significant nonunions or undo clinical effects from galvanic corrosion. A retrospective review was performed of 17 patients with upper-extremity fractures fixed with metal implants of differing metallic compositions. The primary endpoint was fracture union. Eight clavicles, 2 proximal humeri, 3 distal humeri, 3 olecranons, and 1 glenoid fracture with an average follow-up 10 months were reviewed. All fractures healed. One patient experienced screw backout, which did not affect healing. This study implies that mixing implants with differing metallic compositions on the same bone for the treatment of fractures does not adversely affect bone healing. No evidence existed of corrosion or an increase in complications with this method of treatment. Contrary to prior belief, small modular hand stainless steel plates can be used to assist in reduction of smaller fracture fragments in combination with anatomic titanium plates to obtain anatomic reduction of the fracture without adversely affecting healing.

摘要

由于担心发生电偶腐蚀以及随后植入物失效和骨愈合受影响,不同金属成分的植入物一直避免混合使用。本研究的目的是评估使用金属成分不同的金属植入物进行切开复位内固定治疗上肢骨折的情况。作者研究了同时使用不锈钢和钛植入物对骨折愈合、植入物失效以及与这种固定方法相关的其他并发症的影响。他们的假设是,在同一骨头上联合使用这些金属不会导致临床上显著的骨不连或电偶腐蚀产生的不良临床影响。对17例使用不同金属成分的金属植入物固定上肢骨折的患者进行了回顾性研究。主要终点是骨折愈合。回顾了8例锁骨骨折、2例肱骨近端骨折、3例肱骨远端骨折、3例鹰嘴骨折和1例肩胛盂骨折,平均随访10个月。所有骨折均愈合。1例患者出现螺钉退出,但未影响愈合。本研究表明,在同一骨头上混合使用不同金属成分的植入物治疗骨折不会对骨愈合产生不利影响。没有证据表明这种治疗方法会出现腐蚀或并发症增加。与先前的看法相反,小型模块化手部不锈钢钢板可与解剖型钛板联合使用,辅助复位较小的骨折碎片,实现骨折的解剖复位,且不会对愈合产生不利影响。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验