Abstract

Ten primary aromatic amines (AAs) in mainstream cigarette smoke under both ISO and "Health Canada intensive" machine smoking regimens were determined in this work, which were suspected to be carcinogenic compounds. The measured AAs included aniline, ortho-toluidine, meta-toluidine, para-toluidine, 1-naphthylamine, 2-naphthylamine, 3-aminobiphenyl, 4-aminobiphenyl, meta-phenylenediamine and meta-anisidine. For rapidly and sensitively analyzing these AAs, a liquid chromatography-electrospray ionization tandem mass spectrometric (LC-MS/MS) method coupled with solid phase extraction (SPE) was developed. The particulate phase of mainstream cigarette smoke was collected on a Cambridge filter pads, while the gas phase was trapped by 25 mL 5% HCl solution. Then, the pad was extracted in an ultrasonic bath with the impinger HCl solution. After being neutralized with NaOH, the extract was purified with a HLB solid phase extraction column, and then was analyzed with LC-MS/MS using isotope-labeled internal standard. The overall sample pretreatment and analysis time was less than 1.5h. The limits of detection for all targets ranged from 0.05 ng cig(-1) to 0.96 ng cig(-1) with the recoveries in the range of 75.0-131.8%. And the intra-day and inter-day precisions were less than 10% and 16%, respectively. Under HCI machine smoking regimen, the AAs yields in mainstream cigarette smoke were much higher and the average increases were greater than 100% compared with those under ISO smoking condition.

摘要

本工作测定了主流烟气中十种芳香伯胺(AAs),它们均为疑似致癌化合物,这些化合物包括苯胺、邻甲苯胺、间甲苯胺、对甲苯胺、1-萘胺、2-萘胺、3-氨基联苯、4-氨基联苯、间苯二胺和间茴香胺。为了快速灵敏地分析这些 AAs,建立了一种液相色谱-电喷雾串联质谱(LC-MS/MS)与固相萃取(SPE)联用的方法。采用剑桥滤片收集主流烟气的颗粒相,用 25ml5%盐酸溶液捕集气相。然后,将滤片置于超声浴中用冲击瓶盐酸溶液提取。用 NaOH 中和后,用 HLB 固相萃取柱对提取物进行净化,然后用 LC-MS/MS 进行分析,并使用同位素标记的内标。整个样品预处理和分析时间不到 1.5 小时。所有目标物的检出限均在 0.05ng 支(-1)至 0.96ng 支(-1)之间,回收率在 75.0%-131.8%之间。日内和日间精密度分别小于 10%和 16%。在 HCI 机器吸烟条件下,主流烟气中 AAs 的产率明显高于 ISO 吸烟条件下的产率,平均增加超过 100%。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验