Institute for Maternal and Child Health IRCCS Burlo Garofolo, Trieste, Italy.
PLoS One. 2013 Sep 25;8(9):e73939. doi: 10.1371/journal.pone.0073939. eCollection 2013.
Sub-standard quality in X-ray image acquisition and interpretation is common in low-resource countries, and can ultimately result in higher patient morbidity and mortality. This study aimed at evaluating; 1) feasibility of implementing a digital X-ray device in a second level hospital in Angola; 2) quality of digital X-ray images, when digital radiology was in the hands of local technicians; 3) feasibility of digital teleradiology and its potential impact on case management.
We developed and tested at the Hospital Divina Providencia (HDP) in Luanda, Angola, a digital X-ray device and a telemedicine network to acquire and print digital X-ray images and send them as DICOM files for remote consultation.
20,564 digital X-ray images were made at HDP from November 2010 to December 2012, with no major technical problems and no need for on-site supervision. Digital radiology largely improved the number of X-ray images of good and very good quality (100% of images with digital radiology, compared to 15% of screen-film images, p<0.0001). Teleradiology using digital images was used in 7.6% of paediatric cases, and provided, in these cases, an important contribution to case management.
The implementation of a digital X-ray device is feasible in low resource settings with significant improvement in quality of X-ray images compared to standard screen film radiology.
在资源匮乏的国家,X 射线图像采集和解读的质量标准较低的情况很常见,这最终可能导致患者发病率和死亡率上升。本研究旨在评估:1)在安哥拉的一家二级医院实施数字 X 射线设备的可行性;2)当数字放射学由当地技术人员掌握时,数字 X 射线图像的质量;3)数字远程放射学的可行性及其对病例管理的潜在影响。
我们在罗安达的Divina Providencia 医院(HDP)开发并测试了一种数字 X 射线设备和远程医疗网络,以获取和打印数字 X 射线图像,并将其作为 DICOM 文件发送以供远程咨询。
2010 年 11 月至 2012 年 12 月,HDP 共拍摄了 20564 张数字 X 射线图像,没有出现重大技术问题,也无需现场监督。数字放射学大大提高了 X 射线图像的质量(数字放射学的图像 100%为良好和非常好,而屏幕胶片图像为 15%,p<0.0001)。在儿科病例中,有 7.6%使用了数字图像进行远程放射学,这些病例对病例管理有重要贡献。
在资源匮乏的环境中实施数字 X 射线设备是可行的,与标准的屏幕胶片放射学相比,X 射线图像的质量有了显著提高。