Department of Pediatric Nephrology, VU University Medical Center, Amsterdam, The Netherlands; Department of Pediatric Oncology/Hematology, VU University Medical Center, Amsterdam, The Netherlands.
J Pediatr. 2013 Dec;163(6):1722-7. doi: 10.1016/j.jpeds.2013.08.031. Epub 2013 Oct 2.
To compare the diagnostic performance of 2 height-independent equations used to calculate estimated glomerular filtration rate (eGFR), those of Pottel (eGFR-Pottel) and the British Columbia Children's Hospital (BCCH) (eGFR-BCCH), with the commonly used Schwartz equation (eGFR-Schwartz).
We externally validated eGFR-Pottel and eGFR-BCCH in a well-characterized pediatric patient population (n = 152) and compared their diagnostic performance with that of eGFR-Schwartz using Bland-Altman analysis. All patients underwent glomerular filtration rate measurement using the gold standard single-injection inulin clearance method (GFR-inulin).
Median GFR-inulin was 92.0 mL/min/1.73 m² (IQR, 76.1-107.4 mL/min/1.73 m²). Compared with GFR-inulin, the mean bias for eGFR-Schwartz was -10.1 mL/min/1.73 m(2) (95% limits of agreement [LOA], -77.5 to 57.2 mL/min/1.73 m(2)), compared with -12.3 mL/min/1.73 m² (95% LOA, -72.6 to 47.9 mL/min/1.73 m(2)) for eGFR-Pottel and -22.1 mL/min/1.73 m² (95% LOA, -105.0 to 60.8 mL/min/1.73 m(2)) for eGFR-BCCH. eGFR-Pottel showed comparable accuracy to eGFR-Schwartz, with 77% and 76% of estimates within 30% of GFR-inulin, respectively. eGFR-BCCH was less accurate than eGFR-Schwartz (66% of estimates within 30% of GFR-inulin; P < .01).
The performance of eGFR-Pottel is superior to that of eGFR-BCCH and comparable with that of eGFR-Schwartz. eGFR-Pottel is a valid alternative to eGFR-Schwartz in children and could be reported by the laboratory if height data are not available.
比较 2 种不依赖身高的估算肾小球滤过率(eGFR)计算公式——波特(eGFR-Pottel)和不列颠哥伦比亚省儿童医院(BCCH)(eGFR-BCCH)的诊断性能,以及常用的施瓦茨(eGFR-Schwartz)公式。
我们在外周验证了 eGFR-Pottel 和 eGFR-BCCH 在特征明确的儿科患者人群中的性能(n=152),并使用 Bland-Altman 分析比较了它们与 eGFR-Schwartz 的诊断性能。所有患者均使用金标准单剂量注射胰岛素清除法(GFR- 胰岛素)进行肾小球滤过率测量。
中位数 GFR- 胰岛素为 92.0 mL/min/1.73 m²(IQR,76.1-107.4 mL/min/1.73 m²)。与 GFR- 胰岛素相比,eGFR-Schwartz 的平均偏差为-10.1 mL/min/1.73 m²(95%置信区间[LOA],-77.5 至 57.2 mL/min/1.73 m²),而 eGFR-Pottel 为-12.3 mL/min/1.73 m²(95% LOA,-72.6 至 47.9 mL/min/1.73 m²),eGFR-BCCH 为-22.1 mL/min/1.73 m²(95% LOA,-105.0 至 60.8 mL/min/1.73 m²)。eGFR-Pottel 的准确性与 eGFR-Schwartz 相当,分别有 77%和 76%的估计值在 GFR- 胰岛素的 30%以内。eGFR-BCCH 的准确性低于 eGFR-Schwartz(66%的估计值在 GFR- 胰岛素的 30%以内;P<.01)。
eGFR-Pottel 的性能优于 eGFR-BCCH,与 eGFR-Schwartz 相当。eGFR-Pottel 是儿童中替代 eGFR-Schwartz 的有效方法,如果无法获得身高数据,实验室可以报告该方法。