通过手持式光谱域光学相干断层扫描对健康新生儿视神经乳头参数进行量化的种族差异。

Racial variation in optic nerve head parameters quantified in healthy newborns by handheld spectral domain optical coherence tomography.

作者信息

Allingham Michael J, Cabrera Michelle T, O'Connell Rachelle V, Maldonado Ramiro S, Tran-Viet Du, Toth Cynthia A, Freedman Sharon F, El-Dairi Mays A

机构信息

Department of Ophthalmology, Duke Eye Center, Durham, North Carolina.

出版信息

J AAPOS. 2013 Oct;17(5):501-6. doi: 10.1016/j.jaapos.2013.06.014.

Abstract

PURPOSE

To characterize optic nerve head (ONH) morphology and parameters, including vertical disk diameter, vertical cup diameter, and vertical cup/disk ratio in healthy, full-term newborns using a handheld spectral domain optical coherence tomography (SD-OCT) device.

METHODS

In this prospective observational case series, healthy white, black, and Hispanic full-term newborns delivered at the Duke Birthing Center between August 2010 and May 2011 underwent dilated fundus examination and SD-OCT imaging of the optic nerve in each eye. OCT parameters were calculated and compared for each group of infants.

RESULTS

A total of 58 consecutive newborns of white (n = 22), black (n = 15) and Hispanic (n = 21) ethnicity were included. Mean vertical disk diameter in white, black, and Hispanic newborns was 1.29 ± 0.15 mm (standard deviation), 1.38 ± 0.14 mm, and 1.38 ± 0.14 mm, respectively (white versus Hispanic, P = 0.02; white versus black, P = 0.07). Mean vertical cup diameter in white, black, and Hispanic newborns was 0.44 ± 0.15 mm, 0.56 ± 0.23 mm, and 0.46 ± 0.30 mm, respectively (white versus black, P = 0.03). Mean vertical cup/disk ratio was 0.34 ± 0.10 for white, 0.40 ± 0.17 for black, and 0.33 ± 0.20 for Hispanic newborns (P = 0.07 for white versus black).

CONCLUSIONS

Handheld SD-OCT is an effective means of imaging the ONH in newborns. Racial differences in cup/disk ratio are present at birth. These data may serve as the beginning of a normative dataset for characterizing development of the ONH as well as for comparison to the neonatal ONH in disease states.

摘要

目的

使用手持式光谱域光学相干断层扫描(SD-OCT)设备,对健康足月新生儿的视神经乳头(ONH)形态和参数进行特征描述,包括垂直视盘直径、垂直杯盘直径和垂直杯盘比。

方法

在这个前瞻性观察性病例系列中,2010年8月至2011年5月在杜克生育中心出生的健康白人、黑人及西班牙裔足月新生儿接受了散瞳眼底检查和每只眼睛视神经的SD-OCT成像。计算并比较每组婴儿的OCT参数。

结果

共纳入58例连续的白人(n = 22)、黑人(n = 15)和西班牙裔(n = 21)新生儿。白人、黑人和西班牙裔新生儿的平均垂直视盘直径分别为1.29±0.15毫米(标准差)、1.38±0.14毫米和1.38±0.14毫米(白人vs西班牙裔,P = 0.02;白人vs黑人,P = 0.07)。白人、黑人和西班牙裔新生儿的平均垂直杯盘直径分别为0.44±0.15毫米、0.56±0.23毫米和0.46±0.30毫米(白人vs黑人,P = 0.03)。白人新生儿的平均垂直杯盘比为0.34±0.10,黑人新生儿为0.40±0.17,西班牙裔新生儿为0.33±0.20(白人vs黑人,P = 0.07)。

结论

手持式SD-OCT是对新生儿ONH进行成像的有效手段。杯盘比的种族差异在出生时就已存在。这些数据可作为一个规范性数据集的开端,用于描述ONH的发育特征以及与疾病状态下的新生儿ONH进行比较。