Suppr超能文献

应对设计对陶瓷冠颈缘颜色的影响。

Influence of coping design on the cervical color of ceramic crowns.

作者信息

Paniz Gianluca, Kang Ki-Ho, Kim Yongjeong, Kumagai Naota, Hirayama Hiroshi

机构信息

Adjunct Assistant Professor, Graduate and Postgraduate Prosthodontics, Department of Prosthodontics and Operative Dentistry, Tufts University, Boston, Mass; and Visiting Professor, Department of Prosthodontics, University of Padova, Dental School, Padova, Italy.

出版信息

J Prosthet Dent. 2013 Dec;110(6):494-500. doi: 10.1016/j.prosdent.2013.08.005. Epub 2013 Oct 28.

Abstract

STATEMENT OF PROBLEM

The replication of natural teeth, especially with single-tooth restorations, represents a challenge. Similar to metal ceramic crowns, different designs of zirconia substructures have been suggested to improve the esthetic results of zirconia ceramic crowns.

PURPOSE OF STUDY

The purpose of the study was to analyze the color of the cervical portion of single zirconia ceramic crowns fabricated with different zirconia coping designs.

MATERIAL AND METHODS

The color, measured on the CIELAB color scale, of 3 different groups of restorations (n=10) fabricated with zirconia coping (Lava) and feldspathic porcelain (Noritake Super Porcelain) was analyzed with a spectrophotometer. Conventional zirconia crowns with zirconia facial margins were compared with ceramic crowns with porcelain facial margins and either a horizontal reduction of the zirconia coping (1.0 mm reduction) or an additional vertical reduction (1.0 mm additional reduction). The 3 groups, each with a different coping extension, were examined with a 1-way ANOVA and the Fisher exact test, and the differences of the groups were evaluated by applying ΔE thresholds (α=.05).

RESULTS

The mean color difference among all the groups was not clinically significant (ΔE<3.7). Reduced color differences were present between the 2 porcelain butt margin groups of crowns (ΔE=1.06, between group H and V). Increased differences were present between the zirconia margin group and the porcelain butt margin group (ΔE=2.54 between group C and H; ΔE=2.41 between group C and V). Lab* values were examined in all the groups of crowns to determine the clinical implications.

CONCLUSIONS

Within the limitation of the study, no significant differences were present among the tested groups of crowns. Nevertheless, although some differences were present between the zirconia margin group and the porcelain butt margin group, reduced differences were present between the 2 different cutback designs.

摘要

问题陈述

天然牙的复制,尤其是单颗牙修复,是一项挑战。与金属烤瓷冠类似,人们提出了不同设计的氧化锆基底结构,以改善氧化锆陶瓷冠的美学效果。

研究目的

本研究的目的是分析采用不同氧化锆基底设计制作的单颗氧化锆陶瓷冠颈部的颜色。

材料与方法

使用分光光度计分析用氧化锆基底(Lava)和长石质瓷(Noritake Super Porcelain)制作的3组不同修复体(每组n = 10)在CIELAB色表上测量的颜色。将具有氧化锆唇面边缘的传统氧化锆冠与具有瓷唇面边缘且氧化锆基底水平缩减(缩减1.0 mm)或额外垂直缩减(额外缩减1.0 mm)的陶瓷冠进行比较。对3组不同基底延伸的修复体进行单因素方差分析和Fisher精确检验,并通过应用ΔE阈值(α = 0.05)评估组间差异。

结果

所有组之间的平均颜色差异在临床上无显著意义(ΔE < 3.7)。两组瓷对接边缘冠之间的颜色差异减小(H组和V组之间ΔE = 1.06)。氧化锆边缘组与瓷对接边缘组之间的差异增大(C组和H组之间ΔE = 2.54;C组和V组之间ΔE = 2.41)。对所有组的冠进行Lab*值检查以确定临床意义。

结论

在本研究的局限性内,测试的冠组之间没有显著差异。然而,尽管氧化锆边缘组与瓷对接边缘组之间存在一些差异,但两种不同缩减设计之间的差异减小。