Histamine release may underline the side effects (particularly anaphylactoid) of radiographic contrast media. To study the histamine-releasing properties of radiographic contrast media, this study measured the in vitro release of histamine from human basophils incubated with diatrizoate, a standard ionic radiographic contrast agent, and with iopamidol, a newly developed non-ionic contrast agent. The basophils were separated from blood obtained from 16 patients scheduled for coronary angiography. For both diatrizoate and iopamidol, the concentration of histamine released varied as the concentration of radiographic contrast agent was increased from 0.075 M to 0.50 M. At the higher concentrations tested, the percent of histamine released by iopamidol was about half that released by diatrizoate (p less than 0.05). These data suggest that the use of non-ionic contrast media may involve less patient risk from the histamine-mediated allergic and/or hemodynamic side effects associated with radiographic contrast procedures.

摘要

组胺释放可能是放射造影剂副作用(尤其是类过敏反应)的潜在原因。为研究放射造影剂的组胺释放特性,本研究测定了与泛影酸盐(一种标准离子型放射造影剂)和碘帕醇(一种新开发的非离子型造影剂)一起孵育的人嗜碱性粒细胞的组胺体外释放量。嗜碱性粒细胞从16例计划进行冠状动脉造影的患者的血液中分离得到。对于泛影酸盐和碘帕醇,随着放射造影剂浓度从0.075M增加到0.50M,组胺释放浓度也发生变化。在测试的较高浓度下,碘帕醇释放的组胺百分比约为泛影酸盐释放量的一半(p小于0.05)。这些数据表明,使用非离子型造影剂可能会降低患者因放射造影检查相关的组胺介导的过敏和/或血流动力学副作用而产生的风险。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验