Suppr超能文献

[Glass fibre HEPA filters. II. Communication: Microbiological and physico-chemical researchs on used and unusued, hydrophilic and hydrophobic filter materials in an air conditioning plant (author's transl)].

作者信息

Rüden H, Mihm U, Schoemann D, Botzenhart K, Thofern E

出版信息

Zentralbl Bakteriol Orig B. 1975 Jul;160(4-5):525-33.

PMID:242165
Abstract

Hydrophobic and hydrophilic, used and unused HEPA filters from various manufacturers, inoculated with vegetative bacteria, bacterial and fungal spores, were exposed to clean outside air for up to 17 weeks in an air conditioning plant. With relative humidities up to 60%, an increase in germ count could not be found. The rate of killing the micro-organisms inoculated were different and were generally higher on used filters. The low water content of the filter material was apparently not sufficient for microbial growth. In addition, the increase in electric conductivity and reduction of pH value resulting from deposition of substances from the outside air with an acid reaction ascertained in the aqueous filter extracts had a negative effect on the living conditions of the microorganisms.