Abstract

OBJECTIVE

To compare a unidirectional barbed suture (V-Loc™) to its suture material equivalent (Biosyn™) in a single-layer end-to-end anastomosis of equine jejunum.

STUDY DESIGN

Experimental in vitro study.

ANIMALS

Jejunal sections from adult horses (n = 5) without gastrointestinal disease.

METHODS

Jejunal end-to-end anastomoses (n = 9) were performed for each group (V-Loc™, Biosyn™) with a continuous Lembert pattern with an interruption every 120°. Anastomosis construction time, luminal diameter, and number of suture bites were recorded. Anastomosis constructs were distended with fluid at 1 L/min until failure. Location and intraluminal pressure at failure were recorded and all measurements were compared between groups.

RESULTS

V-Loc™ anastomoses were significantly faster to perform (13.1 ± 0.35 minutes) when compared to the Biosyn™ group (15.6 ± 0.72 minutes; P = .0004). No differences were observed for anastomotic index or number of suture bites. V-Loc™ anastomosis constructs had a significantly decreased bursting pressure (160 ± 11.6 mmHg) compared to Biosyn™ constructs (184 ± 16.9 mmHg; P = .01).

CONCLUSIONS

V-Loc™ allowed faster construction time and did not cause a decreased anastomosis luminal diameter when compared with Biosyn™. V-Loc™ had a decreased bursting strength compared with Biosyn™, albeit well above pathologic pressures encountered clinically. Use of V-Loc™ may be beneficial for decreasing the amount of exposed suture material because of the absence of knots after construction and has the potential to result in decreased adhesions.

摘要

目的

在马空肠单层端端吻合术中,将单向倒刺缝线(V-Loc™)与其等效缝线材料(Biosyn™)进行比较。

研究设计

体外实验研究。

动物

选取无胃肠道疾病的成年马的空肠段(n = 5)。

方法

每组(V-Loc™、Biosyn™)进行9次空肠端端吻合,采用连续伦伯特缝合法,每120°间断缝合。记录吻合构建时间、管腔直径和缝合针数。吻合构建物以1 L/min的流速充液直至破裂。记录破裂时的位置和腔内压力,并比较两组之间的所有测量值。

结果

与Biosyn™组(15.6 ± 0.72分钟;P = .0004)相比,V-Loc™吻合术的操作速度明显更快(13.1 ± 0.35分钟)。吻合指数或缝合针数未观察到差异。与Biosyn™构建物(184 ± 16.9 mmHg;P = .01)相比,V-Loc™吻合构建物的破裂压力明显降低(160 ± 11.6 mmHg)。

结论

与Biosyn™相比,V-Loc™缩短了构建时间,且未导致吻合管腔直径减小。与Biosyn™相比,V-Loc™的破裂强度降低,尽管仍远高于临床遇到的病理压力。使用V-Loc™可能有利于减少暴露的缝线材料量,因为构建后没有结,并且有可能减少粘连。