Suppr超能文献

胰腺低剂量全器官CT灌注:初步研究。

Low-dose whole organ CT perfusion of the pancreas: preliminary study.

作者信息

Li Hai-ou, Sun Cong, Xu Zhuo-dong, Miao Fan, Zhang De-jian, Chen Jiu-hong, Li Xiao, Wang Xi-ming, Liu Cheng, Zhao Bin

机构信息

Shandong University Shandong Provincial Medical Imaging Institute, Road jing-wu, No. 324, Jinan, Shandong, 250021, People's Republic of China.

出版信息

Abdom Imaging. 2014 Feb;39(1):40-7. doi: 10.1007/s00261-013-0045-1.

Abstract

OBJECTIVES

To investigate the feasibility of low-dose whole pancreas CT perfusion in the clinical practice.

METHODS

Sixty-one patients suspected pancreatic disease underwent low-dose whole pancreas CT perfusion scan (by body weight, group A: 70 kV, 120 mAs; group B: 80 kV, 100 mAs) and the individualized pancreas scan. Forty-six patients were enrolled. Perfusion characteristics, such as, blood flow, blood volume and permeability, were analyzed. The effective radiation dose of the whole pancreas CT perfusion and the total CT scan protocol were recorded. CT findings were histologically confirmed by surgical intervention or diagnostic puncture.

RESULTS

Of the 46 cases, 33 were pancreatic adenocarcinoma, 5 were solid-pseudo-papillary tumors of pancreas, 8 cases of pancreatic endocrine tumors on the perfusion study. There was significant interobserver agreement on the measurement of normal pancreatic CT perfusion parameters of group A (n = 28)and group B (n = 18), respectively (p > 0.05). For the normal pancreas, there was no significant difference on CT perfusion parameters between group A and group B (p > 0.05). There were significant differences on blood flow as well as blood volume between the pancreatic adenocarcinomas and the normal pancreas (p < 0.001), whereas no difference on the permeability (p > 0.05). The time to peak of the normal pancreas is 28.94 ± 4.37 s (range from 24 to 38 s). Different pancreatic tumors had different types of time attenuation curve (TAC). TACs were different between pancreatic adenocarcinomas and normal pancreas. The effective radiation dose of the whole pancreas CT perfusion of Group A and Group B were 3.60 and 4.88 mSv (DLP 246 and 325 mGy cm), respectively, and the total radiation dose was around 8.01-16.22 mSv.

CONCLUSIONS

Low-dose whole pancreatic CT perfusion can effectively reduce radiation dose, and provide the best phase for the individualized pancreas scan, which has great value in the clinical practice.

摘要

目的

探讨低剂量全胰腺CT灌注成像在临床应用中的可行性。

方法

61例疑似胰腺疾病患者接受了低剂量全胰腺CT灌注扫描(根据体重分组,A组:70 kV,120 mAs;B组:80 kV,100 mAs)及个体化胰腺扫描。纳入46例患者。分析灌注特征,如血流量、血容量和通透性。记录全胰腺CT灌注的有效辐射剂量及总的CT扫描方案。CT表现经手术干预或诊断性穿刺组织学证实。

结果

46例中,33例为胰腺腺癌,5例为胰腺实性假乳头状瘤,8例为胰腺内分泌肿瘤。A组(n = 28)和B组(n = 18)正常胰腺CT灌注参数测量的观察者间一致性良好(p > 0.05)。对于正常胰腺,A组和B组的CT灌注参数无显著差异(p > 0.05)。胰腺腺癌与正常胰腺的血流量及血容量存在显著差异(p < 0.001),而通透性无差异(p > 0.05)。正常胰腺的峰值时间为28.94 ± 4.37 s(范围24至38 s)。不同胰腺肿瘤具有不同类型的时间-密度曲线(TAC)。胰腺腺癌与正常胰腺的TAC不同。A组和B组全胰腺CT灌注的有效辐射剂量分别为3.60和4.88 mSv(剂量长度乘积246和325 mGy·cm),总辐射剂量约为8.01 - 16.22 mSv。

结论

低剂量全胰腺CT灌注可有效降低辐射剂量,并为个体化胰腺扫描提供最佳时相,在临床实践中具有重要价值。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验