Kim Ji-Won, Han Ji-Yen, Kang Min-Hyeok, Ha Sung-Min, Oh Jae-Seop
Department of Rehabilitation Science, Graduate School, Inje University.
J Phys Ther Sci. 2013 Aug;25(8):977-9. doi: 10.1589/jpts.25.977. Epub 2013 Sep 20.
[Purpose] The aim of this study was to compare muscle activity of the posterior oblique sling during prone hip extension (PHE) on the floor and on a round foam roll. [Subjects] Twenty-two (11 male, 11 female) healthy volunteers were recruited for this study. [Methods] The participants performed PHE on the floor and on a round foam roll. Surface electromyography (EMG) was recorded from the contralateral latissimus dorsi (LD), contralateral erector spinae (ES), ipsilateral ES, ipsilateral gluteus maximus (GM), and ipsilateral biceps femoris (IBF). A paired t-test was used to compare muscle activity under the floor and round foam roll conditions. [Results] EMG activity of the contralateral LD, ipsilateral ES, and ipsilateral GM was significantly greater when PHE was performed on the round foam roll than on the floor. [Conclusion] Performing PHE on the round foam roll induced greater posterior oblique sling EMG activity than did exercise on the floor. These results suggest that the activation pattern of the posterior oblique sling during PHE is differs according to the type of surface (stable vs. unstable) on which it is performed.
[目的] 本研究旨在比较在地面和圆形泡沫轴上进行俯卧位髋关节伸展(PHE)时后斜吊索的肌肉活动情况。[对象] 本研究招募了22名(11名男性,11名女性)健康志愿者。[方法] 参与者在地面和圆形泡沫轴上进行PHE。从对侧背阔肌(LD)、对侧竖脊肌(ES)、同侧ES、同侧臀大肌(GM)和同侧股二头肌(IBF)记录表面肌电图(EMG)。采用配对t检验比较在地面和圆形泡沫轴条件下的肌肉活动。[结果] 在圆形泡沫轴上进行PHE时,对侧LD、同侧ES和同侧GM的EMG活动显著高于在地面上进行时。[结论] 在圆形泡沫轴上进行PHE比在地面上运动诱发的后斜吊索EMG活动更大。这些结果表明,PHE期间后斜吊索的激活模式根据其进行的表面类型(稳定与不稳定)而有所不同。