PAM-RL 设备评估睡眠周期性肢体运动的有效性,以及使用该系统评估不安腿综合征或周期性肢体运动障碍患者睡眠中周期性肢体运动夜间变异性的研究。

The validity of the PAM-RL device for evaluating periodic limb movements in sleep and an investigation on night-to-night variability of periodic limb movements during sleep in patients with restless legs syndrome or periodic limb movement disorder using this system.

机构信息

Department of Somnology, Tokyo Medical University, Tokyo, Japan; Japan Somnology Center, Neuropsychiatric Research Institute, Tokyo, Japan; Yoyogi Sleep Disorder Center, Tokyo, Japan.

Japan Somnology Center, Neuropsychiatric Research Institute, Tokyo, Japan; Yoyogi Sleep Disorder Center, Tokyo, Japan.

出版信息

Sleep Med. 2014 Jan;15(1):138-43. doi: 10.1016/j.sleep.2013.08.790. Epub 2013 Oct 31.

Abstract

BACKGROUND

The status of night-to-night variability for periodic limb movements in sleep (PLMS) has not been clarified. With this in mind, we investigated the validity of PLMS measurement by actigraphy with the PAM-RL device in Japanese patients with suspected restless legs syndrome (RLS) or periodic limb movement disorder (PLMD) and the night-to-night variability of PLMS among the subjects.

METHODS

Forty-one subjects (mean age, 52.1±16.1 years) underwent polysomnography (PSG) and PAM-RL measurement simultaneously. Thereafter, subjects used the PAM-RL at home on four more consecutive nights.

RESULTS

The correlation between PLMS index on PSG (PLMSI-PSG) and PLM index on PAM-RL (PLMI-PAM) was 0.781 (P<.001). When the PLMSI cutoff value on PSG was set at 15 episodes per hour, the cutoff value for predicting this PLMSI level was 16.0 episodes per hour. When the condition was set to the level in which the mean interclass correlation coefficient reached ≥0.9, the number of required nights for repeated measurements was 26 nights for subjects with PLMI of <15 episodes per hour and three nights for those with PLMI ≥15 episodes per hour on PAM-RL.

CONCLUSIONS

PAM-RL is thought to be valuable for assessing PLMS even in Japanese subjects. Recording of PAM-RL for three or more consecutive nights may be required to ensure the screening reliability of a patient with suspected pathologically frequent PLMS.

摘要

背景

睡眠周期性肢体运动(PLMS)的夜间变异性状况尚不清楚。考虑到这一点,我们研究了使用 PAM-RL 设备的动作记录仪测量日本疑似不安腿综合征(RLS)或周期性肢体运动障碍(PLMD)患者的 PLMS 的有效性,以及受试者之间的 PLMS 夜间变异性。

方法

41 名受试者(平均年龄 52.1±16.1 岁)同时接受多导睡眠图(PSG)和 PAM-RL 测量。此后,受试者在家中连续四个晚上使用 PAM-RL。

结果

PSG 上的 PLMS 指数(PLMSI-PSG)与 PAM-RL 上的 PLM 指数(PLMI-PAM)之间的相关性为 0.781(P<.001)。当 PSG 上的 PLMSI 截断值设定为 15 个/小时时,预测此 PLMSI 水平的截断值为 16.0 个/小时。当条件设定为平均组内相关系数达到≥0.9 的水平时,对于 PLMI<15 个/小时的受试者,重复测量所需的夜间数为 26 个夜间,对于 PLMI≥15 个/小时的受试者,需要三个夜间。

结论

即使在日本受试者中,PAM-RL 也被认为对评估 PLMS 很有价值。对于疑似病理性频繁 PLMS 的患者,可能需要连续记录 PAM-RL 三个或更多个晚上,以确保筛查的可靠性。