Suppr超能文献

CT 结肠成像与结肠镜检查诊断结直肠癌的准确性比较。

Comparison of the accuracy of CT colonography and colonoscopy in the diagnosis of colorectal cancer.

机构信息

Andalusian Health Technology Assessment (AETSA), Seville, Spain.

出版信息

Colorectal Dis. 2014 Mar;16(3):O82-9. doi: 10.1111/codi.12506.

Abstract

AIM

The available evidence was reviewed to compare the effectiveness of CT colonography with that of colonoscopy for colorectal cancer (CRC) screening.

METHOD

An electronic search was conducted using PubMed, EMBASE, the Cochrane Library and Centre for Reviews and Dissemination databases, from inception to July 2009. Studies were included if investigations used CT colonography for CRC screening in asymptomatic populations. Studies were excluded if investigations were conducted for the diagnosis of CRC or in elderly, high-risk or symptomatic populations.

RESULTS

Of the 213 references identified, nine studies were included. The specificity of CT colonography in screening for CRC was high, although it decreased with decreasing diameter of polyp to be detected. The sensitivity of CT colonography for the detection of polyps < 6 mm in diameter was low and heterogeneous, although it was higher for polyps > 10 mm. The main factors contributing to a greater sensitivity of CT colonography were the inclusion of only populations with an average CRC risk and colonic insufflation with CO2 . The incidence of adverse effects was very low for both tests.

CONCLUSION

CT colonography has high specificity but heterogeneous sensitivity, although in most cases it is not as sensitive or specific as conventional colonoscopy. CT colonography could therefore be useful as a screening test for populations with an average risk of CRC.

摘要

目的

本研究旨在比较 CT 结肠成像与结肠镜在结直肠癌(CRC)筛查中的效果。

方法

检索 PubMed、EMBASE、Cochrane 图书馆和英国国家卫生与临床优化研究所数据库,检索时间截至 2009 年 7 月,纳入使用 CT 结肠成像进行无症状人群 CRC 筛查的研究。排除用于 CRC 诊断或老年、高危或有症状人群的研究。

结果

共检索到 213 篇参考文献,纳入 9 项研究。CT 结肠成像筛查 CRC 的特异性较高,但随着待检息肉直径的减小,特异性降低。CT 结肠成像检测直径 < 6mm 的息肉的敏感性较低且存在异质性,但检测直径 > 10mm 的息肉敏感性较高。提高 CT 结肠成像敏感性的主要因素是仅纳入平均 CRC 风险人群和 CO2 结肠充气。两种检查的不良反应发生率均非常低。

结论

CT 结肠成像具有较高的特异性,但敏感性存在异质性,尽管在大多数情况下,其敏感性或特异性均不如传统结肠镜。因此,CT 结肠成像可作为平均 CRC 风险人群的筛查试验。