Guo Wenbin, Zhang Li, Ji Jun, Gao Wei, Liu Jintao, Tong Meng
Department of Surgery, Breast Center, Dalian Central Hospital, Dalian Medical University, No. 826, Xinan Road, Shahekou District, Dalian, 116033, China,
Tumour Biol. 2014 Apr;35(4):3073-8. doi: 10.1007/s13277-013-1399-2. Epub 2013 Dec 5.
Near-infrared (NIR) fluorescence imaging using indocyanine green (ICG) was considered to have the potential to improve sentinel lymph node (SLN) mapping in breast cancer. Herein, we performed a randomized clinical trial to evaluate the effectiveness of ICG fluorescence imaging compared with blue dye imaging in SLN navigation surgery. We also analyzed lymph drainage pathways to identify targets for sentinel lymph node biopsy (SLNB). Finally, 68 consecutive patients diagnosed with breast cancer and who underwent SLNB between November 2010 and September 2012 were enrolled in the study. The cases were randomly grouped into either the ICG fluorescence or blue dye group, with 36 in the ICG fluorescence group and 32 in the blue dye group. Levels I and II axillary dissection was performed in all cases after SLNB. A single lymph drainage pathway was detected in 21 of 36 (58.3%) patients, and multiple lymph drainage pathways were detected in 15 of 36 (41.7%) cases. The detection rate of SLNB was higher by ICG fluorescence than by blue dye (97.2 vs. 81.3%, p < 0.05), as 3.6 SLNs were detected on average in the ICG fluorescence group compared to 2.1 in the blue dye group. However, the sensitivity and false-negative rate were similar in the two groups. In conclusion, ICG fluorescence was superior to blue dye for the identification of the SLN.
使用吲哚菁绿(ICG)的近红外(NIR)荧光成像被认为有潜力改善乳腺癌前哨淋巴结(SLN)的定位。在此,我们进行了一项随机临床试验,以评估ICG荧光成像与蓝色染料成像在SLN导航手术中的有效性。我们还分析了淋巴引流途径,以确定前哨淋巴结活检(SLNB)的靶点。最后,连续纳入了68例在2010年11月至2012年9月期间被诊断为乳腺癌并接受SLNB的患者。这些病例被随机分为ICG荧光组或蓝色染料组,ICG荧光组36例,蓝色染料组32例。所有病例在SLNB后均进行了Ⅰ级和Ⅱ级腋窝清扫。36例患者中有21例(58.3%)检测到单一淋巴引流途径,36例中有15例(41.7%)检测到多条淋巴引流途径。ICG荧光法对SLNB的检出率高于蓝色染料法(97.2%对81.3%,p<0.05),ICG荧光组平均检测到3.6个SLN,而蓝色染料组为2.1个。然而,两组的敏感性和假阴性率相似。总之,在识别SLN方面,ICG荧光优于蓝色染料。