Suppr超能文献

二维乳腺 X 线摄影与三维乳腺 X 线摄影(断层合成)联合应用的增量效果:基于人群的试验显示,对于筛查中心而言,乳腺癌检出率明显提高。

Incremental effect from integrating 3D-mammography (tomosynthesis) with 2D-mammography: Increased breast cancer detection evident for screening centres in a population-based trial.

机构信息

Centro di Prevenzione Senologica, Marzana, Verona, Italy.

U.O. Senologia Clinica e Screening Mammografico, Department of Diagnostics, Azienda Provinciale Servizi Sanitari (APSS), Trento, Italy.

出版信息

Breast. 2014 Feb;23(1):76-80. doi: 10.1016/j.breast.2013.11.006. Epub 2013 Dec 6.

Abstract

BACKGROUND & OBJECTIVES: Three-dimensional (3D)-mammography (tomosynthesis) may improve breast cancer detection. We examined centre-specific effect of integrated 2D/3D mammography based on the STORM (screening with tomosynthesis or standard mammography) trial.

METHODS

Asymptomatic women who attended population-based screening through Trento and Verona screening centres were recruited into STORM, a prospective comparison of screen-reading in two sequential phases: 2D-mammography only and integrated 2D/3D mammography. Outcomes were the number and rates of detected cancers and of false positive recalls (FPR), and incremental cancer detection rate (CDR). Paired binary data were compared using Mc Nemar's test.

RESULTS

Of 33 cancers detected in Trento, 21 were detected at both 2D and 2D/3D screening, 12 cancers were detected only with integrated 2D/3D screening compared with none detected at 2D-only screening (P < 0.001). Of the 26 cancers detected in Verona, 18 were detected at both 2D and 2D/3D screening, 8 cancers were detected only with integrated 2D/3D screening compared with none detected at 2D-only screening (P = 0.008). There were no differences between centres in baseline CDR, and incremental CDR attributable to 3D-mammography was similar for Trento (2.8/1000 screens) and for Verona (2.6/1000 screens). Trento had 239 FPR (5.7% of screens): 103 FPR at both screen-readings, 93 FPR only at 2D-mammography compared with 43 FPR only at 2D/3D-mammography (p < 0.001). Verona had 156 FPR (5.2% of screens): 78 FPR at both screen-readings, 48 FPR only at 2D-mammography compared with 30 FPR only at 2D/3D-mammography (p = 0.054). Estimated reduction in FPR proportion had recall been conditional to 2D/3D-mammography-positivity differed between centres (21.0% versus 11.5%; P = 0.02).

CONCLUSION

Integrated 2D/3D-mammography significantly increased cancer detection for both screening services; potential reduction in FPR is likely to differ between centres with those experiencing relatively higher FPR most likely to benefit from 2D/3D-mammography screening.

摘要

背景与目的

三维(3D)-乳房 X 线摄影(断层合成)可能会提高乳腺癌的检出率。我们根据 STORM 试验(断层合成或标准乳房 X 线摄影筛查)研究,检查了基于整合 2D/3D 乳房 X 线摄影的中心特异性效果。

方法

无症状女性通过特伦托和维罗纳筛查中心参加人群筛查,被纳入 STORM 前瞻性比较研究,在两个连续阶段进行屏幕阅读:仅 2D 乳房 X 线摄影和整合 2D/3D 乳房 X 线摄影。结果是检测到的癌症数量和检出率(FPR)和增量癌症检出率(CDR)。使用 McNemar 检验比较配对的二项数据。

结果

在特伦托检测到的 33 例癌症中,21 例在 2D 和 2D/3D 筛查中均被检出,12 例癌症仅在整合 2D/3D 筛查中被检出,而在仅 2D 筛查中未检出(P<0.001)。在维罗纳检测到的 26 例癌症中,18 例在 2D 和 2D/3D 筛查中均被检出,8 例癌症仅在整合 2D/3D 筛查中被检出,而在仅 2D 筛查中未检出(P=0.008)。两个中心之间的基线 CDR 无差异,并且断层合成术引起的增量 CDR 在特伦托(2.8/1000 次筛查)和维罗纳(2.6/1000 次筛查)相似。特伦托有 239 例 FPR(5.7%的筛查):2D 阅读时 103 例 FPR,仅在 2D 乳房 X 线摄影中 93 例 FPR,而仅在 2D/3D 乳房 X 线摄影中 43 例 FPR(P<0.001)。维罗纳有 156 例 FPR(5.2%的筛查):2D 阅读时 78 例 FPR,仅在 2D 乳房 X 线摄影中 48 例 FPR,而仅在 2D/3D 乳房 X 线摄影中 30 例 FPR(P=0.054)。如果根据 2D/3D 乳房 X 线摄影的阳性结果对召回进行条件化,那么 FPR 比例的估计减少在中心之间存在差异(21.0%对 11.5%;P=0.02)。

结论

整合 2D/3D 乳房 X 线摄影显著提高了两项筛查服务的癌症检出率;FPR 的潜在降低可能因中心而异,FPR 相对较高的中心最有可能受益于 2D/3D 乳房 X 线摄影筛查。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验