Suppr超能文献

一种用于记录人体心脏心外膜激活的新型袜状电极:通用尺寸。

A new sock electrode for recording epicardial activation from the human heart: one size fits all.

作者信息

Worley S J, Ideker R E, Mastrototaro J, Smith W M, Vidaillet H, Chen P S, Lowe J E

出版信息

Pacing Clin Electrophysiol. 1987 Jan;10(1 Pt 1):21-31. doi: 10.1111/j.1540-8159.1987.tb05921.x.

Abstract

Simultaneous recording of epicardial activation from multiple sites during open heart surgery is essential for studying unstable ventricular arrhythmias. A previously described sock electrode array for this purpose requires custom-woven nylon sock material and expensive machined button electrodes. The limited compliance and elasticity of nylon requires that a new sock be individually fitted for each heart. Despite careful fitting, 17-20% of electrodes do not make satisfactory epicardial contact in dogs. Further, electrodes frequently dislodge from the sock and wires break at the button electrode solder joint. Recognizing these limitations, we formed a new sock from Xspan tubular dressing material and devised electrodes that attach securely to the sock. In six dogs, 90% +/- 3% of electrodes made satisfactory contact using the same Xspan sock, significantly (p less than .01) more than with the nylon sock despite far less labor. The same size X span sock with 60 snap electrodes was used to record from 27 human hearts of widely different dimensions. Satisfactory epicardial contact was obtained in 90% +/- 14% of electrodes in the 18 patients with Wolff-Parkinson-White syndrome (WPW) and 75% +/- 15% of electrodes in the nine patients with coronary artery disease. In no case did an accessory pathway fail to conduct following sock placement. The hemodynamic effect of the Xspan sock was evaluated in four dogs and was found to be minimal. Both the Xspan sock and the snap electrodes are easily made from inexpensive, readily available materials. The same Xspan sock accommodates a wide range of heart sizes, and the electrodes supported by the Xspan sock record significantly better and with less dislodgement and wire breakage than previous socks.

摘要

在心脏直视手术期间同时记录多个部位的心外膜激动对于研究不稳定室性心律失常至关重要。先前描述的用于此目的的袜状电极阵列需要定制编织的尼龙袜材料和昂贵的加工纽扣电极。尼龙的顺应性和弹性有限,需要为每个心脏单独定制新的袜子。尽管安装仔细,但在犬类中仍有17% - 20%的电极与心外膜接触不令人满意。此外,电极经常从袜子上脱落,电线在纽扣电极焊点处断裂。认识到这些局限性,我们用Xspan管状敷料材料制成了一种新袜子,并设计了能牢固附着在袜子上的电极。在6只犬中,使用相同的Xspan袜子时,90%±3%的电极接触良好,尽管工作量少得多,但与尼龙袜相比,显著更多(p<0.01)。使用带有60个按扣电极的相同尺寸的Xspan袜子记录了27个大小差异很大的人心脏的心电情况。在18例预激综合征(WPW)患者中,90%±14%的电极获得了良好的心外膜接触,在9例冠心病患者中,75%±15%的电极获得了良好的心外膜接触。在任何情况下,放置袜子后旁路传导均未失败。在4只犬中评估了Xspan袜子的血流动力学效应,发现其影响极小。Xspan袜子和按扣电极都很容易用便宜且容易获得的材料制成。相同的Xspan袜子可适应广泛的心脏大小,并且由Xspan袜子支撑的电极记录效果明显更好,移位和电线断裂情况比以前的袜子更少。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验