Tyagi Atul, Supe Sanjay S, Singh Man P
Department of Radiation Oncology, BLK Memorial Hospital, New Delhi, India ; Department of Physics, MMH College, Ghaziabad, UP, India.
Department of Radiation Physics, Kidwai Memorial Institute of Oncology, Bangalore, Karnataka, India.
Rep Pract Oncol Radiother. 2010 Sep 22;15(5):125-31. doi: 10.1016/j.rpor.2010.08.002. eCollection 2010.
Intensity modulated radiotherapy (IMRT) is being used to treat carcinoma of cervix (Ca Cx). Integral dose to normal tissue and increased leakage are the concern about IMRT. 6 MV photon beam is a good choice of energy for Ca Cx IMRT treatment.
The objective of this study was to compare intensity modulated radiotherapy (IMRT) plans generated by 6 MV and 15 MV photon energies for carcinoma of cervix (Ca Cx) with regards to dosimetric parameters of planning target volume (PTV) and organs at risk (OAR), homogeneity index (HI), conformity index at 98% level (CI 98%), integral dose to normal tissue (NTID) and total number of monitor units (MUs).
A cohort of 16 patients was selected for this study. All patients were to receive a dose of 50 Gy in 25 fractions. IMRT plans were generated for both energies using same dose-volume constraints.
Our results show a comparable coverage of planning target volume (PTV) for both energies. Volume of PTV receiving a prescription dose is 97.8 ± 0.5% and 98.8 ± 0.4% for the 6 MV and the 15 MV plans. Volume of PTV receiving a dose of 107% is 4.4 ± 7.8% and 16.1 ± 22.2%. Bladder and rectum mean doses for the 6 MV and the 15 MV photon plans were 39.8 ± 3.0 Gy and 40.0 ± 3.2 Gy, and 35.8 ± 3.1 Gy and 36.0 ± 3.1 Gy, respectively. Homogeneity index (HI) for both energies was 1.04. The conformity indices at 98% isodose (CI 98%) were 1.3 ± 0.1 and 1.4 ± 0.1 for 6 MV and 15 MV photon plans, respectively.
We conclude that a 6 MV photon is a good choice for Ca Cx IMRT as it produces a highly conformal, homogeneous plan with superior target coverage and better OAR sparing.
调强放射治疗(IMRT)正用于治疗宫颈癌(Ca Cx)。正常组织的积分剂量和泄漏增加是调强放射治疗所关注的问题。6兆伏光子束是宫颈癌调强放射治疗的理想能量选择。
本研究的目的是比较6兆伏和15兆伏光子能量产生的调强放射治疗(IMRT)计划在宫颈癌(Ca Cx)的计划靶区(PTV)和危及器官(OAR)的剂量学参数、均匀性指数(HI)、98%剂量水平的适形指数(CI 98%)、正常组织的积分剂量(NTID)和监测单位总数(MUs)方面的差异。
本研究选取了16例患者。所有患者均接受25次分割、总剂量50 Gy的治疗。使用相同的剂量体积限制为两种能量生成调强放射治疗计划。
我们的结果显示两种能量对计划靶区(PTV)的覆盖相当。6兆伏和15兆伏计划中接受处方剂量的PTV体积分别为97.8±0.5%和98.8±0.4%。接受107%剂量的PTV体积分别为4.4±7.8%和16.1±22.2%。6兆伏和15兆伏光子计划中膀胱和直肠的平均剂量分别为39.8±3.0 Gy和40.0±3.2 Gy,以及35.8±3.1 Gy和36.0±3.1 Gy。两种能量的均匀性指数(HI)均为1.04。6兆伏和15兆伏光子计划在98%等剂量线的适形指数(CI 98%)分别为1.3±0.1和1.4±0.1。
我们得出结论,6兆伏光子是宫颈癌调强放射治疗的理想选择,因为它能产生高度适形、均匀的计划,具有更好的靶区覆盖和更好的危及器官保护。