Suppr超能文献

基于钴-60源的高剂量率(HDR)近距离放射治疗的剂量学分析:10例子宫颈癌患者的病例系列

Dosimetric analysis of Co-60 source based high dose rate (HDR) brachytherapy: A case series of ten patients with carcinoma of the uterine cervix.

作者信息

Gurjar Om Prakash, Batra Manika, Bagdare Priyusha, Kaushik Sandeep, Tyagi Atul, Naik Ayush, Bhandari Virendra, Gupta Krishna Lal

机构信息

Roentgen-SAIMS Radiation Oncology Centre, Sri Aurobindo Institute of Medical Sciences, Indore, India.

Roentgen-BLK Radiation Oncology Centre, BLK Super Specialty Hospital, New Delhi, India.

出版信息

Rep Pract Oncol Radiother. 2016 May-Jun;21(3):201-6. doi: 10.1016/j.rpor.2016.01.003. Epub 2016 Mar 2.

Abstract

AIM

To analyse the dosimetric parameters of Co-60 based high dose rate (HDR) brachytherapy plans for patients of carcinoma uterine cervix.

BACKGROUND

Co-60 high dose rate (HDR) brachytherapy unit has been introduced in past few years and is gaining importance owing to its long half life, economical benefits and comparable clinical outcome compared to Ir-192 HDR brachytherapy.

MATERIALS AND METHODS

A study was conducted on ten patients with locally advanced carcinoma of the uterine cervix (Ca Cx). Computed tomography (CT) images were taken after three channel applicator insertions. The planning for 7 Gray per fraction (7 Gy/#) was done for Co-60 HDR brachytherapy unit following the American Brachytherapy Society (ABS) guidelines. All the patients were treated with 3# with one week interval between fractions.

RESULTS

The mean dose to high risk clinical target volumes (HRCTV) for D90 (dose to 90% volume) was found to be 102.05% (Standard Deviation (SD): 3.07). The mean D2cc (dose to 2 cubic centimeter volume) of the bladder, rectum and sigmoid were found to be 15.9 Gy (SD: 0.58), 11.5 Gy (SD: 0.91) and 4.1 Gy (SD: 1.52), respectively.

CONCLUSION

The target coverage and doses to organs at risk (OARs) were achieved as per the ABS guidelines. Hence, it can be concluded that the Co-60 HDR brachytherapy unit is a good choice especially for the centers with a small number of brachytherapy procedures as no frequent source replacement is required like in an Ir-192 HDR unit.

摘要

目的

分析基于钴 - 60的高剂量率(HDR)近距离放射治疗计划用于子宫颈癌患者的剂量学参数。

背景

钴 - 60高剂量率(HDR)近距离放射治疗设备在过去几年中已被引入,由于其半衰期长、经济效益以及与铱 - 192 HDR近距离放射治疗相比具有相当的临床疗效,正变得越来越重要。

材料与方法

对10例局部晚期子宫颈癌(Ca Cx)患者进行了一项研究。在插入三通道施源器后进行计算机断层扫描(CT)成像。按照美国近距离放射治疗协会(ABS)指南,为钴 - 60 HDR近距离放射治疗设备制定每次分割剂量为7格雷(7 Gy/#)的计划。所有患者均接受3次分割治疗,分割间隔为1周。

结果

发现高危临床靶区(HRCTV)的D90(90%体积的剂量)平均剂量为102.05%(标准差(SD):3.07)。膀胱、直肠和乙状结肠的平均D2cc(2立方厘米体积的剂量)分别为15.9 Gy(SD:0.58)、11.5 Gy(SD:0.91)和4.1 Gy(SD:1.52)。

结论

按照ABS指南实现了靶区覆盖和对危及器官(OARs)的剂量。因此,可以得出结论,钴 - 60 HDR近距离放射治疗设备是一个很好的选择,特别是对于近距离放射治疗程序较少的中心,因为不像铱 - 192 HDR设备那样需要频繁更换放射源。

相似文献

本文引用的文献

1
Brachytherapy in the treatment of cervical cancer: a review.近距离放射治疗在宫颈癌治疗中的应用:综述
Int J Womens Health. 2014 May 28;6:555-64. doi: 10.2147/IJWH.S46247. eCollection 2014.
5
Comparison of (60)Co and (192)Ir sources in HDR brachytherapy.高剂量率近距离治疗中钴-60源与铱-192源的比较
J Contemp Brachytherapy. 2011 Dec;3(4):199-208. doi: 10.5114/jcb.2011.26471. Epub 2011 Dec 30.