Potter Michael Q, Lawrence Brandon D, Kinikini Daniel V, Brodke Darrel S
Department of Orthopaedics, University of Utah, Salt Lake City, Utah, United States.
Division of Vascular Surgery, University of Utah, Salt Lake City, Utah, United States.
Evid Based Spine Care J. 2013 Oct;4(2):149-53. doi: 10.1055/s-0033-1357358.
Study Design Case report and review of the literature. Objective The objective of the article is to report the case of a 20-year-old patient with a threatened aortic injury from pedicle screw instrumentation successfully managed without aortic grafting. Methods The patient's clinical course is retrospectively reviewed. The offending hardware was removed after gaining endovascular control of the aorta. Results Intraoperative aortography was normal and no graft was placed. The patient remains asymptomatic at 2 years after surgery. Conclusions Hardware impinging on the aorta can safely be removed by gaining endovascular control of the aorta. In the setting of normal intraoperative aortography in a young patient, we recommend against further intervention to avoid the known morbidity of aortic grafting.
研究设计 病例报告及文献综述。目的 本文旨在报告一例20岁患者,其因椎弓根螺钉内固定导致主动脉损伤,在未进行主动脉移植的情况下成功得到处理。方法 对该患者的临床病程进行回顾性分析。在通过血管内手段控制主动脉后,取出了引起问题的内固定物。结果 术中主动脉造影正常,未植入移植物。患者术后2年仍无症状。结论 通过血管内手段控制主动脉后,可以安全地取出压迫主动脉的内固定物。对于年轻患者术中主动脉造影正常的情况,我们建议避免进一步干预,以避免主动脉移植已知的并发症。