Suppr超能文献

髋关节假体周围股骨骨折的钢板内固定是否会导致稳定的髋关节假体柄周围的骨水泥层失效?一项生物力学分析。

Can plate osteosynthesis of periprosthethic femoral fractures cause cement mantle failure around a stable hip stem? A biomechanical analysis.

机构信息

Department of Orthopaedic Surgery, St. Gallen, Switzerland.

Department of Medical Engineering and Physics, Royal Perth Hospital, Perth, Australia.

出版信息

J Arthroplasty. 2014 Jun;29(6):1308-12. doi: 10.1016/j.arth.2013.12.015. Epub 2013 Dec 17.

Abstract

Periprosthetic femoral fractures (PFF) are a serious complication after total hip arthroplasty. Plate fixation with screws perforating the cement mantle is a common treatment option. The study objective was to investigate hip stem stability and cement mantle integrity under dynamic loading. A cemented hip stem was implanted in 17 composite femur models. Nine bone models were osteotomised just distal to the stem and fixed with a polyaxial locking plate the other eight constructs served as the control group. All specimens were tested in a bi-axial material testing machine (100000 cycles). There were no statistically significant differences in axial nor in medial (varus) stem migration. No cement cracks were detected in both groups. Plate fixation of a PFF with a stable, cemented prosthesis did not lead to cement mantle failure in this in vitro study.

摘要

股骨假体周围骨折(PFF)是全髋关节置换术后的一种严重并发症。带穿水泥帽螺钉的钢板固定是一种常见的治疗选择。本研究旨在探讨动态载荷下髋部假体柄的稳定性和水泥帽的完整性。将一个骨水泥固定的髋部假体植入 17 个复合材料股骨模型中。9 个骨模型在假体柄远端进行截骨,并使用多轴锁定钢板固定,其余 8 个作为对照组。所有标本均在双轴材料试验机上进行测试(100000 次循环)。轴向和内侧(内翻)假体柄迁移在两组之间均无统计学显著差异。两组均未发现水泥裂缝。在这项体外研究中,对于稳定的、骨水泥固定的假体周围股骨骨折的钢板固定并未导致水泥帽失效。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验