Suppr超能文献

人工关节周围股骨骨折温哥华B1型的钢板固定:骨水泥壳宏观评估的初步报告及文献综述

Plate fixation in periprosthetic femur fractures Vancouver type B1: preliminary report of macroscopic evaluation of the cement mantle and short literature review.

作者信息

Bibiano Luigi, Stamboltsyan Grigor, Touloupakis Georgios, Ghirardelli Stefano, Biancardi Elena, Longo Giuseppe Edoardo Giovanni, Antonini Guido, Crippa Cornelio

机构信息

Department of Orthopedics and Traumatology, San Carlo Borromeo Hospital, Milan, Italy.

出版信息

Acta Biomed. 2019 Jan 24;90(1):31-36. doi: 10.23750/abm.v90i1.6544.

Abstract

he goal of our preliminary report is to investigate hip stem stability and intra-operative cement mantle integrity after screw insertion in plate fixation of periprosthetic Vancouver B1 femur fractures. From a cohort of 50 patients with a periprosthetic femur fracture treated in our department from February 2012 until February 2017, we included in our study patients with a periprostethic Vancouver B1 femoral fracture in cemented hip arthroplasty and hemiarthroplasty, operated with ORIF using a 4.5/5.0 LCP Proximal Femoral Hook Plate ® (Synthes, Switzerland) with at least one screw perforating the cement mantle. Anteroposterior and lateral femur views and pelvis X-rays were performed preoperatively. The stability of the hip implant and the cemented mantle integrity was evaluated intra-operatively in a macroscopic way and with a post-operative X-ray in anteroposterior and lateral views. Only 7 patients satisfied the inclusion criteria; no lesion/break of the cement mantle occurred intra-operatively at any step during drilling or screw insertion, also confirmed with C-arm assessment. No cases of stem mobilization were found and cement mantle integrity was maintained in every case. Insertion of screws around a cemented stem for plate fixation in periprosthetic femur fractures Vancouver type B1 could be considered a safe procedure. However, further and more extended studies are necessary for proving additional knowledge at the evaluation of the cement mantle in osteosynthesis procedures.

摘要

我们初步报告的目的是研究在人工关节置换周围性温哥华B1型股骨骨折钢板固定中拧入螺钉后髋关节柄的稳定性及术中骨水泥套的完整性。在2012年2月至2017年2月期间在我们科室接受治疗的50例人工关节置换周围性股骨骨折患者队列中,我们纳入了接受骨水泥型髋关节置换术和半髋关节置换术且采用切开复位内固定术治疗的人工关节置换周围性温哥华B1型股骨骨折患者,使用4.5/5.0 LCP近端股骨钩钢板®(瑞士辛迪斯公司),至少有一枚螺钉穿透骨水泥套。术前拍摄股骨正侧位片及骨盆X线片。术中以肉眼观察并于术后拍摄正侧位X线片评估髋关节假体的稳定性及骨水泥套的完整性。只有7例患者符合纳入标准;在钻孔或拧入螺钉的任何步骤中,术中均未发生骨水泥套的损伤/破裂,C形臂评估也证实了这一点。未发现柄松动的病例,且每例均保持了骨水泥套的完整性。在人工关节置换周围性温哥华B1型股骨骨折中,围绕骨水泥柄拧入螺钉进行钢板固定可被认为是一种安全的手术方法。然而,为了在骨合成手术中评估骨水泥套方面获得更多知识,还需要进一步开展更广泛的研究。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/4623/6502151/e7344fe69700/ACTA-90-31-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验