Suppr超能文献

使用两种技术和针具对猫不同部位的核心骨髓活检样本进行比较。

Comparison of feline core bone marrow biopsies from different sites using 2 techniques and needles.

作者信息

Abrams-Ogg Anthony C G, Defarges Alice, Bienzle Dorothee

机构信息

Department of Clinical Studies, Ontario Veterinary College, University of Guelph, Guelph, ON, Canada.

出版信息

Vet Clin Pathol. 2014 Mar;43(1):36-42. doi: 10.1111/vcp.12108. Epub 2014 Jan 28.

Abstract

BACKGROUND

Commonly used 11ga or 13ga biopsy needles are relatively large for cats and often preclude successful collection of bone marrow (BM) core biopsies.

OBJECTIVES

The objective was to compare 15ga to 13ga BM core biopsy ease of collection and specimen quality.

METHODS

In 10 cats, humeral biopsies obtained with 15ga EZ-IO needles were compared with iliac biopsies obtained with 13ga Jamshidi needles. Body condition, ease of collection, section quality, postprocedure pain, and swelling at biopsy sites were scored. Specimen length on mounted slides was measured and specimens with quality scores of 3-5 out of a maximum value of 5 were considered to be of acceptable diagnostic quality. The distribution of all parameters was assessed by Shapiro-Wilk tests, and differences in parameters were assessed by ANCOVA.

RESULTS

There were no significant differences between 15ga and 13ga biopsies, except that the 15ga humeral biopsy was judged to be easier to perform than 13ga iliac biopsy, and there was more severe postbiopsy swelling with 13ga biopsies. Facility score (mean ± SD), section quality score (median ± SD) and specimen length (mm, mean ± SD) were 12.7 ± 2.3, 2.0 ± 1.4, and 6.0 ± 2.1 for 15ga biopsies, respectively, and 8.9 ± 2.4, 1.0 ± 1.8, and 7.5 ± 2.5 for 13ga biopsies, respectively. Three specimens of acceptable quality were obtained with each 15ga and 13ga biopsies.

CONCLUSIONS

In cats, BM biopsy of the humerus with a 15ga needle is easier and causes less postbiopsy swelling than biopsy of the ilium with a 13ga needle. Sites and needles are equivalent with respect to yielding specimens of acceptable quality. Neither technique consistently captured high-quality specimens.

摘要

背景

常用的11号或13号活检针对于猫来说相对较大,常常无法成功采集骨髓(BM)芯活检样本。

目的

比较15号与13号BM芯活检的采集难易程度和样本质量。

方法

对10只猫进行研究,将用15号EZ - IO针获取的肱骨活检样本与用13号Jamshidi针获取的髂骨活检样本进行比较。对身体状况、采集难易程度、切片质量、术后疼痛以及活检部位的肿胀情况进行评分。测量载玻片上样本的长度,质量评分在满分5分中为3 - 5分的样本被认为具有可接受的诊断质量。通过Shapiro - Wilk检验评估所有参数的分布情况,并通过协方差分析评估参数差异。

结果

15号和13号活检之间无显著差异,只是15号肱骨活检被判定比13号髂骨活检更容易操作,且13号活检后肿胀更严重。15号活检的设备评分(均值±标准差)、切片质量评分(中位数±标准差)和样本长度(毫米,均值±标准差)分别为12.7±2.3、2.0±1.4和6.0±2.1,13号活检分别为8.9±2.4、1.0±1.8和7.5±2.5。15号和13号活检均获得了3份质量可接受的样本。

结论

在猫中,用15号针进行肱骨BM活检比用13号针进行髂骨活检更容易,且活检后肿胀更少。就获取质量可接受的样本而言,部位和针具相当。两种技术都不能始终获取高质量样本。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验