Suppr超能文献

长期角膜塑形术停止后眼生物测量和屈光度的短期变化。

Short-term changes in ocular biometry and refraction after discontinuation of long-term orthokeratology.

机构信息

Clínica Oftalmológica Novovision (C.V-C., R.G-O.), Madrid, Spain; Universidad Europea de Madrid (C.V-C.), Madrid, Spain; School of Life and Health Sciences (B.G.), Aston University, Birmingham, United Kingdom; and Menicon Co., Ltd (J.S-R.), Madrid, Spain.

出版信息

Eye Contact Lens. 2014 Mar;40(2):84-90. doi: 10.1097/ICL.0000000000000014.

Abstract

OBJECTIVE

To assess refractive and biometric changes 1 week after discontinuation of lens wear in subjects who had been wearing orthokeratology (OK) contact lenses for 2 years.

METHODS

Twenty-nine subjects aged 6 to 12 years and with myopia of -0.75 to -4.00 diopters (D) and astigmatism of ≤1.00 D participated in the study. Measurements of axial length and anterior chamber depth (Zeiss IOLMaster), corneal power and shape, and cycloplegic refraction were taken 1 week after discontinuation and compared with those at baseline and after 24 months of lens wear.

RESULTS

A hyperopic shift was found at 24 months relative to baseline in spherical equivalent refractive error (+1.86±1.01 D), followed by a myopic shift at 1 week relative to 24 months (-1.93±0.92 D) (both P<0.001). Longer axial lengths were found at 24 months and 1 week in comparison to baseline (0.47±0.18 and 0.51±0.18 mm, respectively) (both P<0.001). The increase in axial length at 1 week relative to 24 months was statistically significant (0.04±0.06 mm; P=0.006). Anterior chamber depth did not change significantly over time (P=0.31). Significant differences were found between 24 months and 1 week relative to baseline and between 1-week and 24-month visits in mean corneal power (-1.68±0.80, -0.44±0.32, and 1.23±0.70 D, respectively) (all P≤0.001). Refractive change at 1 week in comparison to 24 months strongly correlated with changes in corneal power (r=-0.88; P<0.001) but not with axial length changes (r=-0.09; P=0.66). Corneal shape changed significantly between the baseline and 1-week visits (0.15±0.10 D; P<0.001). Corneal shape changed from a prolate to a more oblate corneal shape at the 24-month and 1-week visits in comparison to baseline (both P≤0.02) but did not change significantly between 24 months and 1 week (P=0.06).

CONCLUSIONS

The effects of long-term OK on ocular biometry and refraction are still present after 1-week discontinuation of lens wear. Refractive change after discontinuation of long-term OK is primarily attributed to the recovery of corneal shape and not to an increase in the axial length.

摘要

目的

评估佩戴角膜塑形镜 2 年的患者停止佩戴 1 周后屈光度和眼生物测量学的变化。

方法

29 名年龄在 6 至 12 岁之间、近视屈光度为-0.75 至-4.00 屈光度(D)且散光屈光度≤1.00 D 的患者参与了这项研究。在停止佩戴 1 周后和佩戴 24 个月后,分别测量眼轴长度和前房深度(蔡司 IOLMaster)、角膜曲率和形态以及睫状肌麻痹验光。

结果

与基线相比,24 个月时等效球镜屈光度呈远视漂移(+1.86±1.01 D),随后在 1 周时呈近视漂移(-1.93±0.92 D)(均 P<0.001)。与基线相比,24 个月和 1 周时眼轴长度更长(分别为 0.47±0.18 和 0.51±0.18 mm)(均 P<0.001)。与 24 个月相比,1 周时眼轴长度的增加具有统计学意义(0.04±0.06 mm;P=0.006)。前房深度随时间无显著变化(P=0.31)。与基线相比,24 个月和 1 周时、1 周和 24 个月时,平均角膜曲率存在显著差异(-1.68±0.80、-0.44±0.32 和 1.23±0.70 D)(均 P≤0.001)。与 24 个月相比,1 周时的屈光度变化与角膜曲率的变化密切相关(r=-0.88;P<0.001),但与眼轴长度的变化无关(r=-0.09;P=0.66)。与基线相比,角膜形态在 1 周时发生显著变化(0.15±0.10 D)(P<0.001)。与基线相比,24 个月和 1 周时角膜形状从长轴变扁,更趋于扁形(均 P≤0.02),但在 24 个月和 1 周之间无显著变化(P=0.06)。

结论

停止佩戴角膜塑形镜 1 周后,长期角膜塑形术对眼生物测量和屈光度的影响仍然存在。停止长期角膜塑形治疗后的屈光度变化主要归因于角膜形状的恢复,而不是眼轴长度的增加。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验