在使用或不使用试验性股骨部件的后稳定型全膝关节置换术中进行间隙测量。

Gap measurement in posterior-stabilized total knee arthroplasty with or without a trial femoral component.

作者信息

Hayashi Seiju, Murakami Yuji, Inoue Hiroyuki, Nobutou Hiroo, Nishida Koji, Mochizuki Yu

机构信息

Department of Orthopaedic Surgery, Hiroshima Prefectural Hospital, 1-5-54, Ujinakanda, Minami-ku, Hiroshima, 734-8530, Japan,

出版信息

Arch Orthop Trauma Surg. 2014 Jun;134(6):861-5. doi: 10.1007/s00402-014-1955-2. Epub 2014 Feb 12.

Abstract

PURPOSE

To investigate the effects of a trial femoral component on the intraoperative joint gap and intraoperative joint gap kinematics throughout the range of knee motion in minimally invasive surgery-total knee arthroplasty (MIS-TKA) with the gap technique.

MATERIALS AND METHODS

A total of 103 patients [15 men (15 knees) and 89 women (89 knees)] aged 50-88 years (mean 74.8 years) who received MIS-TKA with the gap technique were included. The intraoperative joint gap differences (90° flexion gap distance minus 0° extension gap distance) with and without the trial femoral component were compared. Subsequently, the intraoperative joint gap kinematics at 0°, 45°, 90°, and 120° with the trial femoral component were investigated.

RESULTS

The intraoperative component gap difference (4.4 ± 2.7 mm) was larger than the estimated joint gap difference (1.2 ± 1.9 mm) (p < 0.01). The mean intraoperative component gap distances at 0°, 45°, 90°, and 120° of knee flexion were 14.7 ± 2.6, 19.0 ± 3.2, 19.2 ± 3.4, and 16.6 ± 3.3 mm, respectively. The intraoperative component gap distance increased significantly from 0° extension to 90° of knee flexion (p < 0.01), and then decreased significantly toward deep knee flexion at 120° (p < 0.01).

CONCLUSIONS

The trial femoral component influenced the intraoperative gap measurements, and increased the intraoperative gap difference. The joint gap kinematics with the trial femoral component were not constant throughout the range of knee motion, even if the appropriate joint gaps in extension and flexion were achieved. For acquisition of constant stability throughout the knee motion, the present results should be taken into account by surgeons performing MIS-TKA with the gap technique.

摘要

目的

采用间隙技术,在微创全膝关节置换术(MIS-TKA)中,研究试验性股骨假体对术中关节间隙及整个膝关节活动范围内术中关节间隙运动学的影响。

材料与方法

纳入103例年龄在50 - 88岁(平均74.8岁)、采用间隙技术接受MIS-TKA的患者,其中男性15例(15膝),女性89例(89膝)。比较使用和不使用试验性股骨假体时的术中关节间隙差异(90°屈曲间隙距离减去0°伸直间隙距离)。随后,研究使用试验性股骨假体时在0°、45°、90°和120°的术中关节间隙运动学。

结果

术中假体间隙差异(4.4±2.7mm)大于估计的关节间隙差异(1.2±1.9mm)(p<0.01)。膝关节屈曲0°、45°、90°和120°时的平均术中假体间隙距离分别为14.7±2.6、19.0±3.2、19.2±3.4和16.6±3.3mm。术中假体间隙距离从0°伸直显著增加至90°膝关节屈曲(p<0.01),然后在120°深度屈膝时显著减小(p<0.01)。

结论

试验性股骨假体影响术中间隙测量,并增加术中间隙差异。即使在伸直和屈曲时获得了合适的关节间隙,使用试验性股骨假体时关节间隙运动学在整个膝关节活动范围内也不是恒定的。为了在整个膝关节活动中获得恒定的稳定性,采用间隙技术进行MIS-TKA的外科医生应考虑本研究结果。