手工器械与 Mtwo 发动机驱动旋转锉进行化学机械预备的体外研究

Chemomechanical preparation by hand instrumentation and by Mtwo engine-driven rotary files, an ex vivo study.

作者信息

Krajczár Károly, Tigyi Zoltán, Papp Viktória, Marada Gyula, Sára Jeges, Tóth Vilmos

机构信息

DMD. Clinical Consultant. Dental School, Faculty of Medicine, University of Pécs, Hungary.

MD, PhD Associate Professor. Department of Medical Microbiology and Immunology, Faculty of Medicine, University of Pécs, Hungary.

出版信息

J Clin Exp Dent. 2012 Jul 1;4(3):e146-50. doi: 10.4317/jced.50733. eCollection 2012 Jul.

Abstract

OBJECTIVE

To compare the disinfecting efficacy of the sodium hypochlorite irrigation by root canal preparation with stainless steel hand files, taper 0.02 and nickel-titanium Mtwo files with taper 0.04-0.06.

STUDY DESIGN

40 extracted human teeth were sterilized, and then inoculated with Enterococcus faecalis (ATCC 29212). After 6 day incubation time the root canals were prepared by hand with K-files (n=20) and by engine-driven Mtwo files (VDW, Munich, Germany) (n=20). Irrigation was carried out with 2.5% NaOCl in both cases. Samples were taken and determined in colony forming units (CFU) from the root canals before and after the preparation with instruments #25 and #35.

RESULTS

Significant reduction in bacterial count was determined after filing at both groups. The number of bacteria kept on decreasing with the extension of apical preparation diameter. There was no significant difference between the preparation sizes in the bacterial counts after hand or engine-driven instrumentation at the same apical size. Statistical analysis was carried out with Mann-Whitney test, paired t-test and independent sample t-test.

CONCLUSIONS

Significant reduction in CFU was achieved after the root canal preparation completed with 2.5% NaOCl irrigation, both with stainless steel hand or nickel-titanium rotary files. The root canal remained slightly infected after chemo mechanical preparation in both groups. Key words:Chemomechanical preparation, root canal disinfection, nickel-titanium, conicity, greater taper, apical size.

摘要

目的

比较使用不锈钢手动锉(锥度0.02)、锥度0.04 - 0.06的镍钛Mtwo锉进行根管预备时次氯酸钠冲洗的消毒效果。

研究设计

40颗拔除的人牙经消毒后,接种粪肠球菌(ATCC 29212)。培养6天后,分别用K锉(n = 20)手工预备根管和用机用Mtwo锉(德国慕尼黑VDW公司)(n = 20)预备根管。两种情况均用2.5%的次氯酸钠冲洗。在使用器械25号和35号预备根管前后,从根管中取样并测定菌落形成单位(CFU)。

结果

两组锉磨后细菌计数均显著降低。随着根尖预备直径的增大,细菌数量持续减少。在相同根尖尺寸下,手工或机用器械预备后细菌计数在预备尺寸方面无显著差异。采用曼 - 惠特尼检验、配对t检验和独立样本t检验进行统计分析。

结论

使用2.5%次氯酸钠冲洗完成根管预备后,无论是使用不锈钢手动锉还是镍钛旋转锉,CFU均显著降低。两组经化学机械预备后根管仍有轻微感染。关键词:化学机械预备;根管消毒;镍钛;锥度;大锥度;根尖尺寸