Suppr超能文献

一种单次测试方案,用于确定临界功率和 W'。

A single-session testing protocol to determine critical power and W'.

机构信息

Heart Foundation Research Centre, Griffith Health Institute, and the School of Allied Health Sciences, Gold Coast Campus, Griffith University, Queensland, 4222, Australia.

出版信息

Eur J Appl Physiol. 2014 Jun;114(6):1153-61. doi: 10.1007/s00421-014-2827-8. Epub 2014 Feb 22.

Abstract

PURPOSE

Critical power (CP), and the finite capacity to perform work above CP (W'), can be determined using a 3-min "all-out" cycling test (3MT). This protocol requires two laboratory visits: an incremental exercise test, followed by a 3MT on a separate day. The purpose of this study was to establish whether an incremental exercise test and a 3MT performed during a single laboratory visit can be used to accurately determine CP and W'.

METHODS

Twelve participants completed two experimental protocols: (1) Combined protocol: an incremental exercise test followed by a 3MT, with 20 min of recovery between exercise bouts; and (2) Independent protocol: the conventional 3MT protocol, performed on a separate day.

RESULTS

CP determined from the Combined (254 ± 117 W) and Independent (256 ± 118 W) protocols were not different (p = 0.40). Similarly, W' was not different (p = 0.96) between the Combined (13.7 ± 3.9 kJ) and Independent (13.7 ± 4.5 kJ) protocols. Linear regression revealed a strong level of measurement agreement between the protocols for CP and W', evidenced by high R(2) values (≥0.85) and marginal standard errors of the estimates (CP = 5 W; W' = 1.81 kJ).

CONCLUSION

A Combined protocol, consisting of an incremental exercise test followed by a 3MT, provides an accurate and valid method to determine an individual's CP and, to a lesser extent, W'. Furthermore, this protocol permits the measurement of the gas-exchange threshold and peak O2 uptake and, consequently, the moderate, heavy, and severe exercise-intensity domains may be defined within a single exercise-testing session.

摘要

目的

临界功率(CP)和在 CP 以上进行有限工作能力(W')可以使用 3 分钟的“全力”骑行测试(3MT)来确定。该方案需要两次实验室访问:递增运动测试,然后在另一天进行 3MT。本研究的目的是确定单次实验室访问期间进行的递增运动测试和 3MT 是否可用于准确确定 CP 和 W'。

方法

十二名参与者完成了两个实验方案:(1)综合方案:递增运动测试后进行 3MT,两次运动之间有 20 分钟的恢复期;(2)独立方案:在另一天进行常规 3MT 方案。

结果

综合方案(254 ± 117 W)和独立方案(256 ± 118 W)确定的 CP 无差异(p = 0.40)。同样,综合方案(13.7 ± 3.9 kJ)和独立方案(13.7 ± 4.5 kJ)的 W'也无差异(p = 0.96)。线性回归显示,CP 和 W'的协议之间具有很强的测量一致性,这表现为高 R²值(≥0.85)和边际估计标准误差(CP = 5 W;W' = 1.81 kJ)。

结论

由递增运动测试后接着进行 3MT 组成的综合方案,提供了一种准确有效的方法来确定个体的 CP,并且在较小程度上可以确定 W'。此外,该方案允许测量气体交换阈值和峰值 O2 摄取量,因此,中等、重度和重度运动强度域可以在单次运动测试中定义。