Abstract

The purpose of this study was to investigate horizontal plane localization and interaural time difference (ITD) thresholds for 14 adult cochlear implant recipients with hearing preservation in the implanted ear. Localization to broadband noise was assessed in an anechoic chamber with a 33-loudspeaker array extending from -90 to +90°. Three listening conditions were tested including bilateral hearing aids, bimodal (implant + contralateral hearing aid) and best aided (implant + bilateral hearing aids). ITD thresholds were assessed, under headphones, for low-frequency stimuli including a 250-Hz tone and bandpass noise (100-900 Hz). Localization, in overall rms error, was significantly poorer in the bimodal condition (mean: 60.2°) as compared to both bilateral hearing aids (mean: 46.1°) and the best-aided condition (mean: 43.4°). ITD thresholds were assessed for the same 14 adult implant recipients as well as 5 normal-hearing adults. ITD thresholds were highly variable across the implant recipients ranging from the range of normal to ITDs not present in real-world listening environments (range: 43 to over 1600 μs). ITD thresholds were significantly correlated with localization, the degree of interaural asymmetry in low-frequency hearing, and the degree of hearing preservation related benefit in the speech reception threshold (SRT). These data suggest that implant recipients with hearing preservation in the implanted ear have access to binaural cues and that the sensitivity to ITDs is significantly correlated with localization and degree of preserved hearing in the implanted ear.

摘要

本研究旨在调查 14 名保听人工耳蜗植入患者在植入耳中的水平平面定位和两耳间时间差(ITD)阈值。在一个 33 个扬声器阵列从-90°延伸到+90°的消声室内评估宽带噪声的定位。测试了三种听力条件,包括双侧助听器、双模式(植入物+对侧助听器)和最佳辅助(植入物+双侧助听器)。在耳机下,对低频刺激(包括 250Hz 音调和 100-900Hz 带通噪声)进行 ITD 阈值评估。与双侧助听器(平均:46.1°)和最佳辅助(平均:43.4°)相比,双模式条件(平均:60.2°)的定位总体均方根误差明显较差。同样对 14 名成年植入者以及 5 名正常听力成年人进行了 ITD 阈值评估。植入者的 ITD 阈值差异很大,范围从正常到现实听力环境中不存在的 ITD(范围:43 至超过 1600 μs)。ITD 阈值与定位、低频听力的两耳间不对称程度以及言语接收阈值(SRT)中与听力保护相关的受益程度高度相关。这些数据表明,在植入耳中有听力保留的植入者可以获得双耳线索,并且对 ITD 的敏感性与定位和植入耳中保留听力的程度显著相关。

相似文献

引用本文的文献

10
The Effects of Middle-ear Stiffness on the Auditory Brainstem Neural Encoding of Phase.中耳劲度对相位听觉脑干神经编码的影响。
J Assoc Res Otolaryngol. 2022 Dec;23(6):859-873. doi: 10.1007/s10162-022-00872-0. Epub 2022 Oct 10.

本文引用的文献

6
Combining acoustic and electric stimulation in the service of speech recognition.声电联合刺激在言语识别中的应用。
Int J Audiol. 2010 Dec;49(12):912-9. doi: 10.3109/14992027.2010.509113. Epub 2010 Sep 27.