Suppr超能文献

使用双倒数图来估计与白蛋白结合的配体的固有摩尔荧光时存在的一个陷阱。

A pitfall in the use of double-reciprocal plots to estimate the intrinsic molar fluorescence of ligands bound to albumin.

作者信息

Panjehshahin M R, Bowmer C J, Yates M S

机构信息

Department of Pharmacology, University of Leeds, U.K.

出版信息

Biochem Pharmacol. 1989 Jan 1;38(1):155-9. doi: 10.1016/0006-2952(89)90162-7.

Abstract

Double-reciprocal plots of fluorescence intensity versus protein concentration are often used to obtain the intrinsic molar fluorescence (Fb) of ligands bound to acceptor molecules such as albumin. In this paper we show that these plots develop upward concave curvature as the concentration of albumin increases. Thus linear extrapolation of such plots cannot be employed to provide accurate values of Fb. It is suggested that a direct plot of fluorescence intensity versus log protein concentration should be employed to obtain Fb.

摘要

荧光强度与蛋白质浓度的双倒数图常用于获得与诸如白蛋白等受体分子结合的配体的固有摩尔荧光(Fb)。在本文中,我们表明随着白蛋白浓度的增加,这些图会出现向上的凹曲率。因此,不能采用此类图的线性外推来提供Fb的准确值。建议采用荧光强度与蛋白质浓度对数的直接图来获得Fb。