The dose received by patients during dental X-ray examination and the technical condition of radiological equipment.

作者信息

Bekas Marcin, Pachocki Krzysztof A

出版信息

Med Pr. 2013;64(6):755-9. doi: 10.13075/mp.5893.2013.0074.

DOI:10.13075/mp.5893.2013.0074
PMID:24645561
Abstract

BACKGROUND

Implementation of X-ray dental examination is associated with the patients exposure to ionizing radation. The size of the exposure depends on the type of medical procedure, the technical condition of the X-ray unit and selected exposure conditions. The aim of this study was to determine the dose received by patients during dental X-ray examination and the assessment of the technical condition of medical equipment,

MATERIALS AND METHODS

The study included a total number of 79 dental X-ray units located in the region of Mazovia. The test methods for the assessment of the technical condition of dental X-ray units and measurement of radiation dose received by patients were based on the procedures elaborated in the Department of Radiation Hygiene and Radiobiology in the National Institute of Public Health - National Institute of Hygiene (Warszawa, Poland) accredited for the certification of compliance with PN-EN 17025.

RESULTS

The research found that 69.6% fully meets the criteria set out in the Polish legislation regarding the safe use of ionizing radiation in medicine, while 30.4% did not meet some of them. A tenfold difference in the size of the dose received by patients during dental X-ray examinations was discovered. For example, during a radiography of the canine teeth of a child, the recorded entrance surface dose (ESD) ranged from 72.8 to 2430 microGy with the average value of 689.1 microGy. Cases where the dose reference level defined in Polish legislation of 5 mGy was exceeded were also found. CONCKUSIONS: It is essential to constantly monitor the situation regarding the technical condition of X-ray units which affects the size of the population's exposure to ionizing radiation as well as raising dentists' awareness about the effects of X-rays on the human body.

摘要

相似文献

1
The dose received by patients during dental X-ray examination and the technical condition of radiological equipment.
Med Pr. 2013;64(6):755-9. doi: 10.13075/mp.5893.2013.0074.
2
Assessing the dose values received by patients during conventional radiography X-ray examinations and the technical condition of the equipment used for this purpose.评估患者在传统X线摄影检查过程中所接受的剂量值以及用于该检查的设备的技术状况。
Med Pr. 2014;65(6):715-21.
3
The assessment of the ionizing radiation dose received by patients during some diagnostic X-ray examinations carried out on the basis of the working procedures in the health care entities.
Rocz Panstw Zakl Hig. 2017;68(1):99-103.
4
Dosages of ionizing radiation during limb diagnostic X-ray examinations.肢体诊断性X线检查期间的电离辐射剂量。
Med Pr. 2016;67(3):321-6. doi: 10.13075/mp.5893.00371.
5
[Evaluation of dental X-ray apparatus in terms of patient exposure to ionizing radiation].[从患者接受电离辐射的角度对牙科X射线设备进行评估]
Med Pr. 2017 Jun 27;68(4):491-496. doi: 10.13075/mp.5893.00506. Epub 2017 May 11.
6
[Diagnostic x-ray examinations in Poland in 2004 in view of the population exposure: the assessment of structure and trends].[2004年波兰基于人群照射的诊断性X线检查:结构与趋势评估]
Med Pr. 2006;57(3):251-6.
7
Radiation protection in dental X-ray surgeries--still rooms for improvement.牙科 X 光手术中的辐射防护——仍有改进的空间。
Br Dent J. 2013 Mar;214(6):E16. doi: 10.1038/sj.bdj.2013.274.
8
Radiation exposure and dose evaluation in intraoral dental radiology.口腔牙科放射学中的辐射暴露与剂量评估
Radiat Prot Dosimetry. 2007;123(2):262-7. doi: 10.1093/rpd/ncl113. Epub 2006 Sep 13.
9
[Analysis of diagnostic X-Ray units in Poland in view of patients' exposure to ionizing radiation].[从患者电离辐射暴露角度对波兰诊断用X射线设备的分析]
Med Pr. 1995;46(2):155-60.
10
Radiation exposure to children in intraoral dental radiology.口腔牙科放射学中儿童的辐射暴露。
Radiat Prot Dosimetry. 2006;121(4):461-5. doi: 10.1093/rpd/ncl071. Epub 2006 Jun 17.

引用本文的文献

1
Measuring the dose-width product and proposing the local diagnostic reference level in panoramic dental radiography: a multi-center study from Iran.测量剂量-宽度乘积并提出全景牙科放射摄影中的局部诊断参考水平:来自伊朗的多中心研究。
Oral Radiol. 2021 Jan;37(1):80-85. doi: 10.1007/s11282-020-00428-z. Epub 2020 Feb 17.