• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

[从患者电离辐射暴露角度对波兰诊断用X射线设备的分析]

[Analysis of diagnostic X-Ray units in Poland in view of patients' exposure to ionizing radiation].

作者信息

Jankowski J, Staniszewska M A

机构信息

Z Zakładu Dozymetrii Promieniowania, Instytutu Medycyny Pracy im. prof. dra med. Jerzego Nofera w Lodzi.

出版信息

Med Pr. 1995;46(2):155-60.

PMID:7637634
Abstract

An analysis of diagnostic X-ray units in Poland is presented. The air-kerma on the X-ray table was measured for X-ray parameters used routinely during lumbo-sacral spine radiography in a standard patient. The measurements were performed using TLD made of lithium-fluoride. The dose received by patients in different X-ray departments is sometimes higher than two orders of magnitude from 0.14 mGy to 72.11 mGy for the same examination. The dose can be significantly reduced if the cassettes with amplyfying foils, made from rare earth components, are used.

摘要

本文介绍了对波兰诊断用X射线设备的分析。在标准患者进行腰骶部脊柱X线摄影时,对X射线检查台上的空气比释动能进行了常规使用的X射线参数测量。测量使用了由氟化锂制成的热释光剂量计。不同X射线科室的患者接受的剂量有时比同一检查的剂量高两个数量级,从0.14毫戈瑞到72.11毫戈瑞不等。如果使用由稀土成分制成的带有增强箔的暗盒,剂量可以显著降低。

相似文献

1
[Analysis of diagnostic X-Ray units in Poland in view of patients' exposure to ionizing radiation].[从患者电离辐射暴露角度对波兰诊断用X射线设备的分析]
Med Pr. 1995;46(2):155-60.
2
[Evaluation of patient exposure to radiation during x-ray diagnostic examinations (in selected health service centers in the city of Wrocław and in the province of Wrocław)].
Med Pr. 1997;48(6):639-50.
3
Assessing the dose values received by patients during conventional radiography X-ray examinations and the technical condition of the equipment used for this purpose.评估患者在传统X线摄影检查过程中所接受的剂量值以及用于该检查的设备的技术状况。
Med Pr. 2014;65(6):715-21.
4
[Diagnostic x-ray examinations in Poland in 2004 in view of the population exposure: the assessment of structure and trends].[2004年波兰基于人群照射的诊断性X线检查:结构与趋势评估]
Med Pr. 2006;57(3):251-6.
5
[Evaluation of patient exposure to X-ray in view of monitoring carried out in diagnostic laboratories of Lódź region].
Med Pr. 2000;51(2):107-14.
6
The assessment of the ionizing radiation dose received by patients during some diagnostic X-ray examinations carried out on the basis of the working procedures in the health care entities.
Rocz Panstw Zakl Hig. 2017;68(1):99-103.
7
Nationwide Evaluation of X-ray Trends survey of abdomen and lumbosacral spine radiography.全国腹部和腰骶椎X线摄影趋势评估调查。
Radiology. 2004 Jul;232(1):115-25. doi: 10.1148/radiol.2321020397.
8
Patient dose and image quality in five standard x-ray examinations.五项标准X线检查中的患者剂量与图像质量
Med Phys. 1993 May-Jun;20(3):813-7. doi: 10.1118/1.596987.
9
The dose received by patients during dental X-ray examination and the technical condition of radiological equipment.
Med Pr. 2013;64(6):755-9. doi: 10.13075/mp.5893.2013.0074.
10
Assessment of annual effective dose due to natural gamma radiation in Zanjan (Iran).伊朗赞詹地区天然伽马辐射所致年有效剂量的评估。
Radiat Prot Dosimetry. 2008;132(3):346-9. doi: 10.1093/rpd/ncn285. Epub 2008 Nov 5.