Suppr超能文献

使用可分离头端微导管栓塞小儿动静脉畸形的安全性和有效性。

Safety and efficacy using a detachable tip microcatheter in the embolization of pediatric arteriovenous malformations.

作者信息

Altschul David, Paramasivam Srinivasan, Ortega-Gutierrez Santiago, Fifi Johanna T, Berenstein Alejandro

机构信息

Center for Endovascular Surgery, Hyman-Newman Institute for Neurology and Neurosurgery, Suite 10G, Mount Sinai-Roosevelt Hospital, 1000 Tenth Ave., New York, NY, 10019, USA,

出版信息

Childs Nerv Syst. 2014 Jun;30(6):1099-107. doi: 10.1007/s00381-014-2404-9. Epub 2014 Mar 27.

Abstract

PURPOSE

The treatment of deep-seeded pediatric brain arteriovenous malformations (AVMs) remains a challenging task. We describe our experience using a new detachable tip microcatheter in the embolization of brain arteriovenous malformations, pial arteriovenous fistulas, and vein of Galen malformations. We describe the safety and efficacy using a new detachable tip microcatheter in the treatment of pediatric deep brain arteriovenous malformations, pial malformations, and vein of Galen malformations.

METHODS

During a period of 9 months from March 2013 through January 2014, 11 pediatric patients in 14 procedures with 27 total injections were selected for treatment with a detachable tip under Food and Drug Administration (FDA) compassionate use exemption and were admitted to our department for treatment of their brain AVM using a liquid embolic agent and a detachable tip microcatheter. The ages of the patients ranged from 3 months to 18 years old.

RESULTS

Of the 27 total injections done, the tip detached in seven cases. For the 16 n-BCA injections, the tip detached six times (37.5 %), and for the 11 Onyx injections, the tip detached one time (9 %). There were no cases of premature microcatheter detachment during normal vessel navigation.

CONCLUSIONS

The introduction of these detachable tip microcatheters allows for a safe and relaxed injection that permits a true circumferential occlusion, and may further permit filling a larger amount of angioarchitecture without the risk of distal migration, or vessel damage during the usual rapid removal of non detachable micocatheters.

摘要

目的

治疗深部小儿脑动静脉畸形(AVM)仍然是一项具有挑战性的任务。我们描述了使用一种新型可分离头端微导管栓塞脑动静脉畸形、软脑膜动静脉瘘和大脑大静脉畸形的经验。我们描述了使用新型可分离头端微导管治疗小儿深部脑动静脉畸形、软脑膜畸形和大脑大静脉畸形的安全性和有效性。

方法

在2013年3月至2014年1月的9个月期间,根据美国食品药品监督管理局(FDA)的同情用药豁免,选择11例儿科患者进行14次手术,共进行27次注射,使用可分离头端微导管,并收入我科,采用液体栓塞剂和可分离头端微导管治疗脑AVM。患者年龄从3个月至18岁不等。

结果

在总共27次注射中,头端分离7例。在16次n-BCA注射中,头端分离6次(37.5%),在11次Onyx注射中,头端分离1次(9%)。在正常血管操作过程中没有发生微导管过早分离的情况。

结论

这些可分离头端微导管的引入使得注射安全、轻松,能够实现真正的环形闭塞,并且可能进一步允许填充更大范围的血管结构,而不会有在快速撤出不可分离微导管时发生远端移位或血管损伤的风险。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验