The aim of the present study was to set up and evaluate a novel method for studies of platelet adhesion and activation in blood and platelet suspensions such as platelet concentrate (PC) samples using protein-coated polystyrene beads and flow cytometry. To demonstrate its usefulness, we studied PCs during storage. PCs were prepared by aphaeresis technique (n = 7). Metabolic variables and platelet function was measured on day 1, 5, 7 and 12 of storage. Spontaneous and TRAP-6-induced adhesion to fibrinogen- and collagen-coated beads was analyzed by flow cytometry. P-selectin and phosphatidyl serine (PS) expression was assessed on platelets bound to beads as well as on non-adherent platelets. Platelet adhesion to fibrinogen beads had increased by day 12 and adhesion to collagen beads at day 7 of storage (p < 0.05). TRAP-6 stimulation significantly increased the platelet adhesion to fibrinogen beads (p < 0.05) as well as the P-selectin and PS exposure on platelets bound to beads (p < 0.01) during the first 7 days of storage, but by day 12, significant changes were no longer induced by TRAP-6 stimulation. We demonstrate that our adhesion assay using protein-coated polystyrene beads can be used to assess the adhesion properties of platelets during storage without the addition of red blood cells. Therefore it may offer a useful tool for future studies of platelet adhesive capacity in transfusion medicine and other settings.

摘要

本研究的目的是建立并评估一种新方法,用于研究血液和血小板悬浮液(如血小板浓缩液(PC)样本)中血小板的黏附和激活情况,该方法使用蛋白包被的聚苯乙烯珠和流式细胞术。为证明其有用性,我们对储存期间的血小板浓缩液进行了研究。通过单采技术制备血小板浓缩液(n = 7)。在储存的第1天、第5天、第7天和第12天测量代谢变量和血小板功能。通过流式细胞术分析血小板对纤维蛋白原和胶原包被珠的自发黏附以及凝血酶受体激活肽-6(TRAP-6)诱导的黏附。评估结合到珠子上以及未黏附的血小板上P-选择素和磷脂酰丝氨酸(PS)的表达。储存至第12天时,血小板对纤维蛋白原珠的黏附增加,储存第7天时对胶原珠的黏附增加(p < 0.05)。在储存的前7天,TRAP-6刺激显著增加了血小板对纤维蛋白原珠的黏附(p < 0.05)以及结合到珠子上的血小板上P-选择素和PS的暴露(p < 0.01),但到第12天时,TRAP-6刺激不再诱导显著变化。我们证明,使用蛋白包被的聚苯乙烯珠的黏附试验可用于评估储存期间血小板的黏附特性,而无需添加红细胞。因此,它可能为输血医学和其他环境中血小板黏附能力的未来研究提供一个有用的工具。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验