通过显微计算机断层扫描评估三种镍钛器械系统对根管形态的影响。

Effects of three nickel titanium instrument systems on root canal geometry assessed by micro-computed tomography.

作者信息

Gergi R, Osta N, Bourbouze G, Zgheib C, Arbab-Chirani R, Naaman A

机构信息

Department of Endodontics, Saint-Joseph University, Beirut, Lebanon.

出版信息

Int Endod J. 2015 Feb;48(2):162-70. doi: 10.1111/iej.12296. Epub 2014 May 12.

Abstract

AIM

To compare and evaluate the shaping ability of several nickel titanium instrument systems with different motions: two reciprocating single-file systems (Reciproc and WaveOne) and one continuous rotation/reciprocation full-sequence system [Twisted File (TF) Adaptive] using micro-computed tomography.

METHODOLOGY

A total of forty-eight mesial canals of mandibular molars with two separate root canals and severe angles of curvature were selected. Canals were divided randomly to one of three experimental groups: group 1, reciprocating instrumentation with Reciproc R25, group 2, reciprocating with the Primary WaveOne file and group 3 'Adaptive Rotary Motion' with Twisted Files. Each group consisted of 16 root canals. Canals were scanned before and after root canal preparation, with a resolution of 20 μm using a micro-computed tomography system. The following parameters were assessed: changes in dentine volume, percentage of unshaped canal walls, degree of canal transportation and centring ability. Data were analysed using analysis of variance and Tukey's post hoc tests test to explore a significant difference in mean dentine removal, mean percentage of noninstrumented canals, mean degree of canal transportation and centring ratio between groups in the apical third and along the entire root canal. The level of significance was set at α = 0.05.

RESULTS

Preoperatively, there were no differences regarding root canal curvature and volume between experimental groups (P > 0.05). Overall instrumentation led to enlarged canal shapes with no evidence of preparation errors. None of the three groups was able to shape completely the root canal system. Mean dentine removal along the entire canal and in the apical third was significantly higher with Reciproc when compared with TF Adaptive and WaveOne (P = 0.013). Mean degree of canal transportation was significantly lower with TF Adaptive (P < 0.0001) followed by WaveOne and highest with Reciproc in the apical third and along the entire root canal.

CONCLUSIONS

None of the NiTi systems was able to instrument completely the entire root canal. Reciprocation and Adaptive Motions were found to cut dentine efficiently to full working length, with no procedural errors. The TF Adaptive system maintained the original canal anatomy with less canal transportation and better centring ability.

摘要

目的

使用微型计算机断层扫描技术,比较和评估几种具有不同运动方式的镍钛器械系统的根管预备能力:两种往复式单根器械系统(Reciproc和WaveOne)和一种连续旋转/往复式全序列系统[Twisted File(TF)Adaptive]。

方法

共选取48颗下颌磨牙的近中根管,这些根管有两个独立的根管且弯曲度较大。将根管随机分为三个实验组之一:第1组,使用Reciproc R25进行往复式根管预备;第2组,使用WaveOne初尖锉进行往复式根管预备;第3组,使用Twisted File进行“自适应旋转运动”根管预备。每组包含16个根管。在根管预备前后使用微型计算机断层扫描系统对根管进行扫描,分辨率为20μm。评估以下参数:牙本质体积变化、未预备根管壁的百分比、根管偏移程度和就位能力。使用方差分析和Tukey事后检验分析数据,以探究根尖三分之一处及整个根管内各组之间在平均牙本质去除量、未预备根管的平均百分比、平均根管偏移程度和就位率方面的显著差异。显著性水平设定为α = 0.05。

结果

术前,实验组之间在根管弯曲度和体积方面无差异(P > 0.05)。总体根管预备使根管形态扩大,未发现预备错误。三组均未能完全预备根管系统。与TF Adaptive和WaveOne相比,Reciproc在整个根管及根尖三分之一处的平均牙本质去除量显著更高(P = 0.013)。TF Adaptive的平均根管偏移程度显著更低(P < 0.0001),其次是WaveOne,Reciproc在根尖三分之一处及整个根管内的平均根管偏移程度最高。

结论

没有一种镍钛系统能够完全预备整个根管。发现往复式运动和自适应运动能够有效地将牙本质切割至工作长度,且无操作失误。TF Adaptive系统能更好地保持根管原始解剖结构,根管偏移更少,就位能力更好。