Suppr超能文献

一种用于检测雌激素受体激动剂的机器人BG1Luc报告基因检测法。

A robotic BG1Luc reporter assay to detect estrogen receptor agonists.

作者信息

Stoner Matthew A, Yang Chun Z, Bittner George D

机构信息

CertiChem, Inc., Austin, TX, USA.

CertiChem, Inc., Austin, TX, USA; Neuroscience Department, University of Texas, Austin, TX, USA.

出版信息

Toxicol In Vitro. 2014 Aug;28(5):916-25. doi: 10.1016/j.tiv.2014.03.013. Epub 2014 Apr 18.

Abstract

Endocrine disrupting chemicals with estrogenic activity (EA) have been associated with various adverse health effects. US agencies (ICCVAM/NICEATM) tasked to assess in vitro transcription activation assays to detect estrogenic receptor (ER) agonists for EA have recently validated a BG1Luc assay in manual format, but prefer robotic formats. We have developed a robotic BG1Luc EA assay to detect EA that demonstrated 100% concordance with ICCVAM meta-analyses and ICCVAM BG1Luc results in manual format for 27 ICCVAM test substances, i.e. no false negatives or false positives. This robotic assay also consistently assessed other, more problematic ICCVAM test substances such as clomiphene citrate, L-thyroxin, and tamoxifen. Agonist responses using this robotic BG1Luc assay were consistently inhibited by the ER antagonist ICI 182,780, confirming that agonist responses were due to binding to ERs rather than to a non-specific agonist response. This robotic assay also detected EA in complex mixtures of substances such as extracts of personal care products, plastic resins or plastic consumer products. This robotic BG1Luc assay had at least as high accuracy and greater sensitivity and repeatability when compared to its manual version or to the other ICCVAM/OECD validated assays for EA (manual BG1Luc and CERI).

摘要

具有雌激素活性(EA)的内分泌干扰化学物质已与多种不良健康影响相关联。美国机构(ICCVAM/NICEATM)负责评估体外转录激活试验以检测EA的雌激素受体(ER)激动剂,最近已验证了手动格式的BG1Luc试验,但更倾向于机器人格式。我们开发了一种用于检测EA的机器人BG1Luc试验,该试验对于27种ICCVAM测试物质,与ICCVAM荟萃分析和手动格式的ICCVAM BG1Luc结果显示出100%的一致性,即无假阴性或假阳性。这种机器人试验还持续评估了其他更具问题的ICCVAM测试物质,如柠檬酸氯米芬、L-甲状腺素和他莫昔芬。使用这种机器人BG1Luc试验的激动剂反应始终受到ER拮抗剂ICI 182,780的抑制,证实激动剂反应是由于与ER结合而非非特异性激动剂反应所致。这种机器人试验还检测了物质复杂混合物中的EA,如个人护理产品提取物、塑料树脂或塑料消费品。与手动版本或其他ICCVAM/OECD验证的EA试验(手动BG1Luc和CERI)相比,这种机器人BG1Luc试验具有至少同样高的准确性、更高的灵敏度和可重复性。

相似文献

本文引用的文献

8
Our plastic age.我们的塑料时代。
Philos Trans R Soc Lond B Biol Sci. 2009 Jul 27;364(1526):1973-6. doi: 10.1098/rstb.2009.0054.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验