Dilworth Lowell L, McGrowder Donovan A, Thompson Rory K
Department of Pathology, University of the West Indies, Mona Campus, Kingston, Jamaica.
Indian J Clin Biochem. 2014 Apr;29(2):227-31. doi: 10.1007/s12291-013-0348-6. Epub 2013 May 29.
This study evaluated the types and frequencies of pre-examination errors recorded in the chemical pathology laboratory at the University Hospital of the West Indies, Jamaica. This was a retrospective analysis of errors recorded over a three year period. Data analysis was done on an average of 519,084 samples collected and tested per year. Samples included blood, urine, stool and other fluids. Pre-examination errors were identified and recorded following visual inspection of the samples and corresponding request forms by laboratory staff, then subsequently by the Senior Medical Technologist. Errors were generally classified as inappropriate sample (58 %), inappropriate form (23.4 %), inappropriate sample volume (9.3 %) and inappropriate sample tube (9.3 %). Over 90 % of recorded pre-examination errors were related to blood samples while urine samples accounted for 6.8 % error. Pre-examination errors were lower at this study location than elsewhere. Measures aimed at reducing instances of these errors are recommended for improved laboratory quality output.
本研究评估了牙买加西印度大学医院化学病理实验室记录的检验前误差的类型和频率。这是对三年期间记录的误差进行的回顾性分析。每年平均对519,084份采集和检测的样本进行数据分析。样本包括血液、尿液、粪便和其他体液。实验室工作人员首先通过目视检查样本和相应的申请表来识别和记录检验前误差,随后由高级医学技术专家进行检查。误差通常分为样本不合适(58%)、申请表不合适(23.4%)、样本量不合适(9.3%)和样本管不合适(9.3%)。记录的检验前误差中超过90%与血液样本有关,而尿液样本的误差占6.8%。该研究地点的检验前误差低于其他地方。建议采取措施减少这些误差的发生,以提高实验室的质量产出。