Suppr超能文献

心包积气:起搏器植入术后心房电极穿孔的一种罕见并发症。

Pneumopericardium: an uncommon complication of atrial lead perforation following pacemaker implantation.

作者信息

Higny Julien, Blommaert Dominique

出版信息

Acta Cardiol. 2014 Apr;69(2):213-5. doi: 10.1080/ac.69.2.3017308.

Abstract

Cardiac perforation is an infrequent but potentially life-threatening complication of pacemaker implantation. We report a case of right atrial lead perforation complicated by pneumopericardium shortly after pacemaker lead insertion. Transthoracic echocardiography revealed no evidence of pericardial effusion and pacemaker lead displacement, but a thoracic computed tomography scan illustrated the lead course and confirmed the diagnosis. This case suggests that computed tomography is a sensitive modality to confirm the diagnosis at the early stage of this complication.

摘要

心脏穿孔是起搏器植入术罕见但可能危及生命的并发症。我们报告一例起搏器导线插入后不久发生的右心房导线穿孔并伴有心包积气的病例。经胸超声心动图未显示心包积液和起搏器导线移位的证据,但胸部计算机断层扫描显示了导线走行并确诊。该病例提示计算机断层扫描是在这种并发症早期确诊的敏感方法。