Suppr超能文献

计算机化髁突路径角评估的可靠性。

The reliability of computerized condylar path angle assessment.

作者信息

Schierz O, Klinger N, Schön G, Reissmann D R

出版信息

Int J Comput Dent. 2014;17(1):35-51.

Abstract

Recording the track of the mandibular hinge axis and consequently ascertaining the posterior determinants is one of the key requirements for accurately simulating individual oral conditions in the (virtual) articulator. The aim of this study was to determine the reliability of computerized condylar path inclination angle (CPIA) measures and to assess whether the reliability depends on the mandibular dentition. Sagittal and transverse CPIA were measured using computerized axiography (Cadiax Compact 2) at two separate sessions in prosthodontic patients (mean age +/- SD: 64.3 +/- 10.3 years; female: 45%) who were classified into three dentition categories (fully dentate: N = 19, partially dentate: N = 27 and edentulous: N = 19). These measurements were repeated three times at both sessions without removing the computerized axiograph. Reliability was assessed in multilevel analyses using the subject as a grouping variable in linear random-intercept models. Considering all assessment procedures, the patient-specific differences explained 75% of the variance for the sagittal and 38% for the transverse condylar path. This corresponds to the overall reliability of both the sagittal and the transverse CPIA assessment. The dentition had no significant impact on the reliability of the measurements. The sagittal CPIA can be assessed with satisfactory reliability using computerized axiography. It is independent of the status of the dentition, which has no statistically significant impact on the measures. Transverse CPIA measurements have shown poor reliability. Therefore, the electronic determination of the sagittal CPIA is a reliable procedure that can be applied in patients irrespective of the status of the mandibular dentition.

摘要

记录下颌铰链轴轨迹并据此确定后部定位因素是在(虚拟)牙合架中准确模拟个体口腔状况的关键要求之一。本研究的目的是确定计算机化髁突路径倾斜角(CPIA)测量的可靠性,并评估该可靠性是否取决于下颌牙列情况。在义齿修复患者(平均年龄±标准差:64.3±10.3岁;女性:45%)中,使用计算机化轴面绘图仪(Cadiax Compact 2)在两个不同时间段测量矢状面和横断面的CPIA,这些患者被分为三类牙列情况(全口牙列完整:N = 19,部分牙列缺失:N = 27,无牙颌:N = 19)。在两个时间段内,不取下计算机化轴面绘图仪,对这些测量重复进行三次。在多水平分析中,以受试者作为分组变量,在线性随机截距模型中评估可靠性。考虑所有评估程序,患者个体差异解释了矢状面髁突路径75%的方差和横断面髁突路径38%的方差。这对应于矢状面和横断面CPIA评估的总体可靠性。牙列情况对测量的可靠性没有显著影响。使用计算机化轴面绘图仪可以以令人满意的可靠性评估矢状面CPIA。它与牙列状况无关,牙列状况对测量没有统计学上的显著影响。横断面CPIA测量显示可靠性较差。因此,矢状面CPIA的电子测定是一种可靠的程序,可应用于下颌牙列状况不同的患者。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验