Suppr超能文献

磁共振成像(MRI)在金属对金属髋关节置换术后的表现及其与金属离子水平和髋臼倾斜角度的关系。

MRI findings following metal on metal hip arthroplasty and their relationship with metal ion levels and acetabular inclination angles.

机构信息

Lourdes Orthopaedic Hospital, Kilcreene, Kilkenny, Ireland.

School of Mathematical Sciences, University College Dublin, Belfield, Dublin 4, Ireland.

出版信息

J Arthroplasty. 2014 Aug;29(8):1647-52. doi: 10.1016/j.arth.2014.03.030. Epub 2014 Mar 29.

Abstract

Following the global recall of all ASR metal on metal hip products, our aim was to correlate MRI findings with acetabular inclination angles and metal ion levels in patients with these implants. Both cobalt and chromium levels were significantly higher in the presence of a periprosthetic fluid collection. There was no association between the presence of a periprosthetic mass, bone marrow oedema, trochanteric bursitis or greater levels of abductor muscle destruction for cobalt or chromium. There was no association between the level of periprosthetic tissue reaction and the acetabular inclination angle with any of the pathologies identified on MRI. The relationship between MRI pathology, metal ion levels and acetabular inclination angles in patients with ASR implants remains unclear adding to the complexity of managing patients.

摘要

在全球召回所有 ASR 金属对金属髋关节产品后,我们的目的是将 MRI 结果与这些植入物患者的髋臼倾斜角度和金属离子水平相关联。在存在假体周围积液的情况下,钴和铬的水平明显更高。在假体周围肿块、骨髓水肿、转子滑囊炎或更大程度的外展肌破坏的存在与钴或铬之间没有关联。假体周围组织反应水平与髋臼倾斜角度与 MRI 上确定的任何病理学之间没有关联。ASR 植入物患者的 MRI 病理学、金属离子水平和髋臼倾斜角度之间的关系仍然不清楚,这增加了患者管理的复杂性。