Gibson R S, Gibson I L, Webber C E, Atkinson S A
Department of Family Studies, University of Guelph, Ontario, Canada.
Biol Trace Elem Res. 1988 Sep-Dec;17:139-49. doi: 10.1007/BF02795452.
The fecal monitoring technique for measuring the absorption of Zn, Mn, Se, and Fe was studied in eight male piglets (mean +/- SEM birthweight (bw) = 1695 +/- 50 g) using high resolution gamma spectrometry. Four d old piglets were fed a complete liquid milk diet for five d prior to the orogastric administration of an isotope dose (75Se, 54Mn, 59Fe, and 65Zn) equilibrated with the liquid milk diet. 51CrCl3 was used as a fecal marker but was found to be partially absorbed. Stool samples were collected daily for 15 d, counted, and then the daily fecal excretion was calculated. Results indicate that endogenous excretion for each of the isotopes was not constant but decreased exponentially with time. The pattern of endogenous excretion varied between elements. An improved method for calculating the endogenous excretion was therefore developed. This method is based on the pattern of endogenous excretion in three-four d old male piglets (mean +/- SEM bw = 2060 +/- 75 g) injected intravenously with the same isotopes and on the level of endogenous excretion in orally fed animals in the postabsorptive phase of excretion. These findings have important implications for the estimation of endogenous excretion in future fecal monitoring absorption studies in order to minimize underestimation of true absorption.
利用高分辨率γ能谱法,在八只雄性仔猪(平均±标准误出生体重(bw)=1695±50g)中研究了测量锌、锰、硒和铁吸收的粪便监测技术。在经口胃管给予与液态奶日粮平衡的同位素剂量(75硒、54锰、59铁和65锌)之前,4日龄仔猪先饲喂全液态奶日粮5天。51氯化铬用作粪便标记物,但发现其有部分吸收。每天收集粪便样本,持续15天,进行计数,然后计算每日粪便排泄量。结果表明,每种同位素的内源性排泄并非恒定不变,而是随时间呈指数下降。内源性排泄模式因元素而异。因此,开发了一种改进的计算内源性排泄的方法。该方法基于对静脉注射相同同位素的3-4日龄雄性仔猪(平均±标准误bw=2060±75g)内源性排泄模式以及口服给药动物在排泄吸收后阶段内源性排泄水平的研究。这些发现对于未来粪便监测吸收研究中内源性排泄的估计具有重要意义,以便尽量减少对真实吸收的低估。