Abstract

OBJECTIVE

To evaluate the compliance of patients while wearing maxillary Hawley retainers embedded with SMART microsensors.

METHODS

The sample population consisted of 22 patients who were divided into an experimental (group A) and a control group (group B). Group A was informed that they would be monitored through the use of SMART microsensors, while group B was not informed that they would be monitored. After the delivery of the retainers (T0), the patients were evaluated at T1 and T2, represented by 6- and 12-week follow-up visits, respectively. At T1, group B was informed of our ability to monitor their compliance. Both groups continued wearing their retainers during T1 to T2.

RESULTS

During T0-T1, Group A wore their retainers for an average of 16.3 hours (SD 4.39), while group B wore their appliances for an average of 10.6 hours (SD 5.36, t  =  2.426, P  =  .027). Although group B increased their retainer wear by 0.5 hours/day from T1 to T2, this increase was not statistically significant.

CONCLUSIONS

Despite significant differences being noted between the two groups at T1, group B did not show significant mean changes in their wear time before and after becoming aware of the use of the SMART microsensor.

摘要

目的

评估佩戴嵌入SMART微传感器的上颌霍利保持器时患者的依从性。

方法

样本群体由22名患者组成,分为实验组(A组)和对照组(B组)。A组被告知他们将通过使用SMART微传感器进行监测,而B组未被告知他们将被监测。在交付保持器后(T0),分别在T1和T2对患者进行评估,T1和T2分别代表6周和12周的随访。在T1时,告知B组我们监测其依从性的能力。两组在T1至T2期间继续佩戴保持器。

结果

在T0 - T1期间,A组平均佩戴保持器16.3小时(标准差4.39),而B组平均佩戴矫治器10.6小时(标准差5.36,t = 2.426,P = .027)。尽管B组从T1到T2每天增加保持器佩戴时间0.5小时,但这一增加无统计学意义。

结论

尽管两组在T1时存在显著差异,但B组在知晓使用SMART微传感器前后的佩戴时间没有显著的平均变化。

相似文献

8
Microsensor technology to help monitor removable appliance wear.用于帮助监测可摘矫治器佩戴情况的微传感器技术。
Am J Orthod Dentofacial Orthop. 2009 Apr;135(4):549-51. doi: 10.1016/j.ajodo.2008.06.021.

引用本文的文献

4
Wearable Orofacial Technology and Orthodontics.可穿戴口腔技术与正畸学
Dent J (Basel). 2023 Jan 10;11(1):24. doi: 10.3390/dj11010024.
7
Orthodontic Compliance Assessment: A Systematic Review.正畸依从性评估:系统评价。
Int Dent J. 2022 Oct;72(5):597-606. doi: 10.1016/j.identj.2022.07.004. Epub 2022 Aug 10.

本文引用的文献

3
Effects of wear time recording on the patient's compliance.佩戴时间记录对患者依从性的影响。
Angle Orthod. 2013 Nov;83(6):1002-8. doi: 10.2319/010913-25.1. Epub 2013 Apr 25.
10
Microsensor technology to help monitor removable appliance wear.用于帮助监测可摘矫治器佩戴情况的微传感器技术。
Am J Orthod Dentofacial Orthop. 2009 Apr;135(4):549-51. doi: 10.1016/j.ajodo.2008.06.021.