Suppr超能文献

动脉自旋标记稳态自由进动快速成像(ASL-FISP):一种用于高场磁共振成像的快速定量灌注技术。

Arterial spin labeling-fast imaging with steady-state free precession (ASL-FISP): a rapid and quantitative perfusion technique for high-field MRI.

作者信息

Gao Ying, Goodnough Candida L, Erokwu Bernadette O, Farr George W, Darrah Rebecca, Lu Lan, Dell Katherine M, Yu Xin, Flask Chris A

机构信息

Department of Radiology, Case Western Reserve University, Cleveland, OH, USA; Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA.

出版信息

NMR Biomed. 2014 Aug;27(8):996-1004. doi: 10.1002/nbm.3143. Epub 2014 Jun 3.

Abstract

Arterial spin labeling (ASL) is a valuable non-contrast perfusion MRI technique with numerous clinical applications. Many previous ASL MRI studies have utilized either echo-planar imaging (EPI) or true fast imaging with steady-state free precession (true FISP) readouts, which are prone to off-resonance artifacts on high-field MRI scanners. We have developed a rapid ASL-FISP MRI acquisition for high-field preclinical MRI scanners providing perfusion-weighted images with little or no artifacts in less than 2 s. In this initial implementation, a flow-sensitive alternating inversion recovery (FAIR) ASL preparation was combined with a rapid, centrically encoded FISP readout. Validation studies on healthy C57/BL6 mice provided consistent estimation of in vivo mouse brain perfusion at 7 and 9.4 T (249 ± 38 and 241 ± 17 mL/min/100 g, respectively). The utility of this method was further demonstrated in the detection of significant perfusion deficits in a C57/BL6 mouse model of ischemic stroke. Reasonable kidney perfusion estimates were also obtained for a healthy C57/BL6 mouse exhibiting differential perfusion in the renal cortex and medulla. Overall, the ASL-FISP technique provides a rapid and quantitative in vivo assessment of tissue perfusion for high-field MRI scanners with minimal image artifacts.

摘要

动脉自旋标记(ASL)是一种有价值的非对比灌注磁共振成像(MRI)技术,具有众多临床应用。许多先前的ASL MRI研究使用了回波平面成像(EPI)或稳态自由进动真快速成像(真FISP)读出方式,这些方式在高场MRI扫描仪上容易出现失谐伪影。我们为高场临床前MRI扫描仪开发了一种快速ASL-FISP MRI采集方法,可在不到2秒的时间内提供几乎没有伪影的灌注加权图像。在这个初始实施方案中,将流敏感交替反转恢复(FAIR)ASL准备与快速、中心编码的FISP读出相结合。对健康的C57/BL6小鼠进行的验证研究在7和9.4 T时提供了一致的体内小鼠脑灌注估计值(分别为249±38和241±17 mL/min/100 g)。该方法的实用性在缺血性中风C57/BL6小鼠模型中显著灌注缺陷的检测中得到进一步证明。对于在肾皮质和髓质中表现出不同灌注的健康C57/BL6小鼠,也获得了合理的肾脏灌注估计值。总体而言,ASL-FISP技术为高场MRI扫描仪提供了一种快速且定量的体内组织灌注评估方法,图像伪影最少。

相似文献

引用本文的文献

本文引用的文献

8
Ischemic stroke in mice and rats.小鼠和大鼠的缺血性中风。
Methods Mol Biol. 2009;573:95-114. doi: 10.1007/978-1-60761-247-6_6.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验