Suppr超能文献

基于开口压力测量的脑动脉瘤夹特性:使用高压灌注回路和猪血管的基础研究

[Characteristics of cerebral aneurysm clips based on measurements of the opening pressures: basic research using a high-pressure perfusion circuit and a porcine vessel].

作者信息

Mizuniwa Yoshitaka, Tanaka Yuichiro, Ito Hidemichi, Oshio Kotaro

机构信息

Department of Neurosurgery, St. Marianna University School of Medicine.

出版信息

No Shinkei Geka. 2014 Jun;42(6):523-9.

Abstract

BACKGROUND

The closing force of cerebral aneurysm clips is measured according to International Organization for Standardization guidelines. However, it is difficult to predict the risk of a clip using only the closing force. To investigate the clips' detailed characteristics and assess their limits, we used a high-pressure perfusion circuit and measured the critical pressure to the slipping point.

METHODS

Opening pressures were measured for 3 types of Sugita clips using a high-pressure perfusion circuit and a porcine vessel. The opening pressures at different points on various blade lengths and shapes were also measured.

RESULTS

The opening pressure of a short blade clip was higher than that of a long one. In a straight blade of the same length, the opening pressure of the proximal segment of a blade was higher than that at the distal segment.

CONCLUSIONS

Our study showed the characteristics of various clips, such as blade length. These findings suggested that clips should be chosen on a case-by-case basis.

摘要

背景

脑动脉瘤夹的闭合力是根据国际标准化组织的指南进行测量的。然而,仅使用闭合力很难预测夹子的风险。为了研究夹子的详细特性并评估其局限性,我们使用了一个高压灌注回路,并测量了达到滑脱点时的临界压力。

方法

使用高压灌注回路和猪血管对3种类型的杉田夹进行开启压力测量。还测量了各种叶片长度和形状在不同点的开启压力。

结果

短叶片夹的开启压力高于长叶片夹。在相同长度的直叶片中,叶片近端的开启压力高于远端。

结论

我们的研究显示了各种夹子的特性,如叶片长度。这些发现表明应根据具体情况选择夹子。